Safety Alert for Patient Data Manager and Origin Data Management

According to Department of Health, this safety alert involved a device in Hong Kong that was produced by Brainlab.

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Date
    2015-09-29
  • Event Date Posted
    2015-09-29
  • Event Country
  • Event Source
    DH
  • Event Source URL
  • Notes / Alerts
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Extra notes in the data
    Medical Device Safety Alert
  • Reason
    Medical device safety alert: brainlab patient data manager and origin data management the medicines and healthcare products regulatory agency (mhra), united kingdom posted a medical device safety alert concerning patient data manager and origin data management manufactured by brainlab. the affected devices are identified as follows: content manager (versions 2.0.0, 2.0.1, 2.0.2, 2.0.3, 2.1.0); patient browser (versions 4.0.0, 4.0.1, 4.0.2, 4.0.3, 4.1.0) and dicom viewer (versions 2.0.0, 2.0.1, 2.0.2, 2.0.3, 2.1.0). according to the alert, when users actively deselect a fused reference dataset in content manager (the default setting is “selected”), a contained point, object or trajectory may appear shifted and/or distorted in the subsequently used brainlab navigation or planning software. if a reference dataset is deselected and the error occurs, the magnitude of shift or distortion varies, depending on the differences between the two datasets. therefore, for some cases, the shift or distortion will be clearly visible when the plan is used in a brainlab planning or navigation system. however, a shift could also be non-obvious. if a shift or distortion occurred and was not detected during review of the data, the deviation of the information displayed in the brainlab planning or navigation software could mislead the user regarding clinical decisions. this could ultimately lead to ineffective treatment, serious injury or even death of the patient. for details, please refer to the mhra website:https://www.Gov.Uk/government/publications/safety-information-from-manufacturers-field-safety-notices/field-safety-notices-21-to-25-september-2015 if you are in possession of the affected products, please contact your supplier for necessary actions posted on 29 september 2015.

Device

  • Model / Serial
  • Product Description
    Medical Device Safety Alert: Brainlab Patient Data Manager and Origin Data Management
  • Manufacturer

Manufacturer