Safety Alert for Infinia nuclear medicine systems; VG and VG Hawkeye nuclear medicine systems; Helix nuclear medicine systems; Brivo NM615; Discovery NM630; Optima NM/CT640; and Discovery NM/CT 670

According to Department of Health, this safety alert involved a device in Hong Kong that was produced by GE Healthcare.

What is this?

Alerts provide important information and recommendations about products. Even though an alert has been issued, it does not necessarily mean a product is considered to be unsafe. Safety Alerts, addressed to health workers and users, may include recalls. They can be written by manufacturers, but also by health officials.

Learn more about the data here
  • Type of Event
    Safety alert
  • Date
    2013-07-05
  • Event Date Posted
    2013-07-05
  • Event Country
  • Event Source
    DH
  • Event Source URL
  • Notes / Alerts
    Hong Kong data is current through September 2018. All of the data comes from the Department of Health (Hong Kong), except for the categories Manufacturer Parent Company and Product Classification.
    The Parent Company and the Product Classification were added by ICIJ.
    The parent company information is based on 2017 public records. The device classification information comes from FDA’s Product Classification by Review Panel, based on matches of data from the U.S. and Hong Kong.
  • Extra notes in the data
    Medical Device Safety Alert
  • Reason
    Medical device safety alert: ge healthcare nuclear medicine systems it has come to our attention that medical device manufacturer, ge healthcare has initiated a field safety corrective action concerning its nuclear medicine systems. the affected products are 1) infinia nuclear medicine systems; 2) vg and vg hawkeye nuclear medicine systems; 3) helix nuclear medicine systems; 4) brivo nm615; 5) discovery nm630; 6) optima nm/ct640; and 7) discovery nm/ct 670. on 5 june 2013, ge healthcare became aware of an incident in the united states that a patient died due to injuries sustained while being scanned on an infinia hawkeye 4 due to a portion of the system falling onto the patient during the scan. investigation by the manufacturer found that bolts securing the camera to the gantry were loose, thereby stressing the support mechanism and resulting in the incident. because of the similarities in the design of support mechanisms across many products, the manufacturer has included all types and manufacturing dates of infinia and infinia hawkeye nuclear medicine systems; all types and manufacturing dates of vg and vg hawkeye nuclear medicine systems; and all types and manufacturing dates of helix nuclear medicine systems by elscint ltd. the manufacturer stated that the issue should also affected brivo nm615, discovery nm630, optima nm/ct640, discovery nm/ct670 due to similarities in basic mechanical concepts between these devices and the infinia systems. ge healthcare will inspect all affected systems to verify that the support mechanism fasteners are secured properly. furthermore, ge healthcare recommends that users to cease use of their nuclear medicine system until ge healthcare can complete an inspection of their system. according to the local supplier, the affected products are distributed in hong kong. if you are in possession of the product, please contact your supplier for necessary actions. posted on 05 july 2013.

Device

  • Model / Serial
  • Product Classification
  • Product Description
    Medical Device Safety Alert: GE Healthcare nuclear medicine systems