FIBERNET Embolic Protection System

Manufacturer

  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Manufacturers representative
    Tamer Frères S.A.L.
  • Source
    RLMPH

3 devices with a similar name

Learn more about the data here

  • Model / Serial
    US Model Number FBC350500190, lot number 1E029174; Internation Model number FBN350500190; lot 1E012912.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US including the states of IL, PA, MA, VA. RI and LA., and the countries of Germany, Italy, Poland, Romania, Saudi Arabia, Kosovo, Slovakia and Spain.
  • Product Description
    FIBERNET Embolic Protection System: || Recommended Vessel Diameter 3.5 0 5.0 mm, Maximum Guidewire Diameter: 0.014 in ( 0.36 mm) || Rx only, Sterile; || Manufactured in: || Invatec S.P.A., Italy; || Manufacturer: || Medtronic Inc. || Minneapolis, MN. || The FiberNet Embolic Protection System is indicated for use as a guidewire and emboli protection system to capture and remove embolic material (thrombus/debris) produced while performing percutaneous transluminal interventional procedures in carotid arteries in high surgical risk patients with reference vessel diameters of 3.5 mm to 7.0 mm.
  • Manufacturer
  • Model / Serial
    US Model Number FBC 500600190, lot number 1E029176; International Model Number FBN500600190, lot number 1E012914.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US including the states of IL, PA, MA, VA. RI and LA., and the countries of Germany, Italy, Poland, Romania, Saudi Arabia, Kosovo, Slovakia and Spain.
  • Product Description
    FIBERNET Embolic Protection System: || Recommended Vessel Diameter 5.0 -6.0 mm, Maximum Guidewire Diameter: || 0.014 in (0.36mm) || Rx only, Sterile; || Manufactured in: || Invatec S.P.A., Italy; || Manufacturer: || Medtronic Inc. || Minneapolis, MN. || The FiberNet Embolic Protection System is indicated for use as a guidewire and emboli protection system to capture and remove embolic material (thrombus/debris) produced while performing percutaneous transluminal interventional procedures in carotid arteries in high surgical risk patients with reference vessel diameters of 3.5 mm to 7.0 mm.
  • Manufacturer
  • Model / Serial
    US Model Number FBC 600700190, lot number 1E029750; International Model Number: FBN600700190: lot numbers 1E012916, 1E017817.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US including the states of IL, PA, MA, VA. RI and LA., and the countries of Germany, Italy, Poland, Romania, Saudi Arabia, Kosovo, Slovakia and Spain.
  • Product Description
    FIBERNET Embolic Protection System: || Recommended Vessel Diameter 6.0 -7.0 mm, Maximum Guidewire Diameter: || 0.014 in (0.36mm) || Rx only, Sterile; || Manufactured in: || Invatec S.P.A., Italy; || Manufacturer: || Medtronic Inc. || Minneapolis, MN. || The FiberNet Embolic Protection System is indicated for use as a guidewire and emboli protection system to capture and remove embolic material (thrombus/debris) produced while performing percutaneous transluminal interventional procedures in carotid arteries in high surgical risk patients with reference vessel diameters of 3.5 mm to 7.0 mm.
  • Manufacturer