Worldwide, including Algeria, Argentina, Australia, Bangladesh, Brazil, Cambodia, Chile, Egypt, France, Hong Kong, India, Italy, Jordan, Lebanon, Malaysia, Pakistan, Peru, Philippines, Russia, S Africa, S Korea, Spain, Thailand, Turkey, United Kingdon, & Vietnam
Product Description
Esprit Ventilator, Model Number V1000, Power Supply PN 1015852 and Power Supply Field Replacement Unit (FRU) PN, Continuous Ventilator/Continuous Ventilator with Respiratory Mechanics 1018246
Nationwide, plus Australia, Argentina, Canada, Japan, Hong Kong, Netherlands, Saudi Arabia, & Taiwan
Product Description
Ventilator-PLV Continuum (PLVC I), Model Number: P1000. The PLVC I is a microprocessor controlled, compressor-based, mechanical ventilator. It is intended to control or assist breathing by delivering room air to the patient. It utilizes an internal compressor to generate compressed air for delivery to the patient. Breath delivery is controlled by software algorithms. The PL VC I user interface has a membrane keypad with indicator Light Emitting Diodes for the selection and acceptance of patient settings and for the display of alarm conditions. PL VC I provides the following types of ventilatory support: || 1) Positive Pressure Ventilation, delivered either invasively (via endotracheal or tracheostomy tube) or non-invasively (via mask or mouthpiece ). || 2) Assist/Control, Spontaneous Intermittent Mandatory Ventilation (SIMV)or Continuous Positive Airway Pressure (CPAP) modes of ventilation. || 3) Volume-Controlled (VC). Available in AlC and SIMV. || 4) Pressure-Controlled (PC). Available in AlC and SIMV. || 5) Pressure Support (PS). Available in SIMV and SPONT.
Nationwide, Taiwan, Saudi Arabia, Netherlands, Hong Kong, Canada, Brazil, Australia, and Argentina.
Product Description
The PL V Continuum ventilator is a microprocessor controlled, compressorbased, mechanical ventilator. It is intended to control or assist breathing by delivering room air to the patient. PL V Continuum utilizes an internal compressor to generate compressed air for delivery to the patient. Breath delivery is controlled by software algorithms. The user interface on PL V Continuum has a membrane keypad with indicator Light Emitting Diodes (LED) for the selection and acceptance of patient settings and for the display of alarm conditions. PL V Continuum is capable of providing the following types of ventilatory support: || . Positive Pressure Ventilation, delivered either invasively (via endotracheal or tracheostomy tube) or non-invasively (via mask or mouthpiece). || . Assist/Control, Spontaneous Intermittent Mandatory Ventilation (SIMV) or Continuous Positive Airway Pressure (CP AP) modes of ventilation. || . Volume-Controlled (VC). Available in AlC and SIMV. || . Pressure-Controlled (PC). Available in AlC and SIMV. || . Pressure Support (PS). Available in SIMV and SPONT.