Medtronic Inc, Neurological & Spinal Division

6 devices in the database

  • Model / Serial
    NJH701951H thru NJH801963H, NJH701965H, NJH701967H thru NJH701969H, NJH701971H thru NJH701975H, NJH701978H thru NJH701986H, NJH702007H, NJH702008H, NJH702028H, NJH702029H, NJH702032H, NJH702033H, NJH702035H, NJH702036H, NJH702038H, NJH702039H, NJH702044H, NJH702045H, NJH702144H, NJH702145H, NJH702146H, NJH702150H, NJH702152H, NJH702153H, NJH702157H, NJH702158H, NJH702159H, NJH702160H, NJH702162H, NJH702163H, NJH702164H, NJH702166H, NJH702168H, NJH702169H, NJH702171H thru NJH702175H, NJH702183H, NJH702184H, NJH702213H, NJH702215H, NJH702216H, NJH702263H, NJH702324H, NJH702425H, NJH702427H, NJH702428H, NJH702429H, NJH702434H, NJH702436H, NJH702438H, NJH702439H, NJH702441H, NJH702443H, NJH702447H, NJH702451H, NJH702452H, NJH702455H, NJH702458H, NJH702487H, NJH702765H, NJH702772H, NJH702809H, NJH702834H, NJH702852, NJH702862H, NJH702863H, NJH702919H, NJH702980, NJH702982H, NJH702990H, NJH702993H, NJH702999H, NJH703001H
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Nationwide (AZ, CA, FL, ID, IL, IN, KS, KY, MA, MD, MI, MO, NC, NJ, NV, NY, OH, PA, SC, TN, TX, VA, WA, and WI).
  • Product Description
    Medtronic Model 37711 Restore Neurostimulator. The Restore Neurostimulator is an implanted, rechargeable neurostimulator which provides pain management therapy.
  • Model / Serial
    All serial numbers and Lot codes are affected.
  • Product Classification
  • Device Class
    3
  • Implanted device?
    Yes
  • Distribution
    Nationwide and OUS to includeCanada, Europe, Middle East, Africa, Japan, Asia-Pacific, Australia - New Zealand, Latan America
  • Product Description
    Medtronic Activa Deep Brain Stimulation (DBS) system including the following system components: Model 7424 Itrel II Neurostimulator (DBS applications only); Model 7426 Soletra Neurostimulator; Model 7428 Kinetra Neurostimulator; Models 3387, 3389 DBS Leads; and Models 7482,7495 DBS Extensions. Medtronic, Inc. 710 Medtronic Parkway, Minneapolis, MN 55432-5604, USA. The Medtronic Activa System is an implantable, multiprogrammable system that delivers electrical stimulation to selected areas of the brain. The Neurostimulator generates electrical signals that are transmitted to the brain. These signals are delivered from the neurostimulator to the brain via Extension and Lead. These components comprise the implantable portion of the Activa System.
  • Model / Serial
    N0016487
  • Product Classification
  • Device Class
    3
  • Implanted device?
    Yes
  • Distribution
    within the United States only
  • Product Description
    Model 8561 Lioresal (Baclofen injection) Intrathecal Refill Kit is designed for refilling the Medtronic SynchroMed family of pumps. The 8561 kit contains a 1-20 ml ampule of 500 mcg/ml Baclofen injection along with a sterile refill kit tray and sterile drug preparation tray. || Lioresal drug ampules contained witin Medtronic Lot N0016487 bear the primary manufacturer''s label and lot number 007J2583. The drug box is labeled with Lot 017H1925. || Medtronic packages a manufacturer''s labeled ampule into a protective drug box. A lot number and drug lot expiration date are printed on the outside of the drug box. The filled and labeled drug box is placed inside a larger kit assembly that contains other components necessary to complete a pump refill. Only the large kit assembly (''Lioresal Refill Kit'') will display the Medtronic lot number (N0016487). || The Model 8561 refill kit does not have a product code for itself; it is approved under PMA P860004. PMA P860004 is classified as: pump infusion, implanted, programmable under product code LKK.
  • Model / Serial
    Software Version AAA 02, BBB 04, BBC 02, and BBD 01
  • Product Classification
  • Device Class
    3
  • Implanted device?
    Yes
  • Distribution
    These cards were distributed primarily in the USA, but also to countries in Europe, Middle East and Africa, Canada, Australia, Hong Kong, Latin America and Japan.
  • Product Description
    8870 software application card versions AAA 02, BBB 04, BBC 02, and BBD 01, which is used in conjunction with the Model 8840 N''Vision Clinician Programmer.
  • Model / Serial
    CS0293
  • Product Classification
  • Device Class
    3
  • Implanted device?
    Yes
  • Distribution
    US and one customer in New Zealand.
  • Product Description
    The Model 8540 Catheter Access Port Kit is intended for use in accessing the catheter via the catheter access port of Medtronic(R) implantable programmable infusion pumps (except Medtronic MiniMed pumps). The Model 8540 Catheter Access Port Kit does not have a product code for itself; it is approved under PMA P860004. PMA P860004 is classified as: pump, infusion, implanted, programmable under product code LKK.
One more