Mako Surgical Corporation

11 devices in the database

  • Model / Serial
    Lot #K081867
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Nationwide distribution: NY only.
  • Product Description
    MAKO PN 204588 Camera || 204588 Label With Camera Stand Number ***PN 200294 SN CAM XXX 2011-01.*** Weight 86.2kg.***Class I Equipment. Conforms to IEC 60601-1/A2: 1995, EN 60601-1/A2: 1995, UL 60601-1: 2003, CAN/CSA-C22.2 No. 601.1-M90.*** Manufactured in USA*** MAKO SURGICAL CORP. 2555 Davie Road, Ft. Lauderdale, FL 33317.*** || 204589 Robot Arm Label***PN 203999 SN ROB XXX 2011-01.***V 100/120/230 A 9.6/8.0/4.2 Hz 50/60***Weight 39.4kg***Class I Equipment Conforms to IEC 60601-1/A2: 1995, EN 60601-1/A2: 1995, UL 60601-1:2003 CAN/CSA-C22.2 No. 601-1-M90.***Manufactured in USA***MAKO SURGICAL CORP. 2555 Davie Road, Ft. Lauderdale, FL 33317.*** || 204588 Label With Guidance Module Number***PN 201251 SN GUD XXX 2011-01***Weight 51.7kg***Class I Equipment. Conforms to IEC 60601-1/A2: 1995, En 60601-1/A2: 1995, UL 60601-1: 2003, CAN/CSA-C22.2 No. 601.1-M90***Manufactured in USA***MAKO SURGICAL CORP. 2555 Davie Road, Ft. Lauderdale, FL 33317.*** || THE RIO uses an infra-red camera for the purpose of spatial navigation. This camera is present on the Camera Stand and communicates with the Guidance Module to provide the locations of the tracked instruments (i.e. robotic-arm, patient trackers, probes, etc). The information is then used to provide the virtual representation of the patient anatomy and the tools on the monitor, and provides necessary information to the robotic-arm to ensure proper bone preparation.
  • Model / Serial
    Lot numbers: ROB034, ROB035, ROB036, ROB037, ROB038, ROB042, ROB044, ROB045, ROB046, ROB047, ROB048, ROB049, ROB050, ROB051, ROB053, ROB054, ROB055, ROB056, ROB057, ROB059, ROB060, ROB061, ROB062, ROB062, ROB063, ROB066, ROB067, ROB069, ROB070, ROB071, ROB072, ROB073, ROB074, ROB075, ROB076, ROB077, ROB078, ROB079, ROB080, ROB081, ROB082, ROB083, ROB084, ROB085, ROB086, ROB088, ROB093, ROB094, ROB096, ROB097, ROB098, ROB099, ROB100, ROB101, ROB102, ROB103, ROB104, ROB107, ROB108, ROB109, ROB110, ROB112, ROB114, ROB116, ROB117, ROB118, ROB120, ROB121, ROB122, ROB123, ROB124.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide distribution: USA including states of: AZ, CA, CO, FL, GA, IA, IL, LA, MI, MO, MS, NC, NJ, NV, NY, OK, OH, OR, PA, RI, TX, UT, VA, WA, WI, and WV; and countries of: Scotland, Italy and Korea.
  • Product Description
    Labeling for RIO Robot Unit is comprised of three main components: 20399 RIO SURGICAL ARM, 201251 RIO GUIDANCE MODULE, 200294 RIO CAMERA STAND ASSEMBLY***PN 203999 SN ROB 125 2010-12 V 100/120/230 A 9.6/8.0/4.2 Hz 50/60 Class I Equipment. Conforms to IEC 60601-1/A2: 1995, EN 60601-1/A2: 1995 UL 60601-1: 2003, CAN/CSA-C22.2 No. 601.1-M90.***Manufactured in USA***MAKO SURGICAL CORP. 2555 DAVIE ROAD, FT. LAUDERDALE, FL 33317. || RIO System - The Tactile Guidance System v2.0 is intended to assist the surgeon in providing software defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures. The Tactile Guidance System v2.0 is indicated for use in surgical knee procedures, in which the use of stereotactic surgery may be approriate, and where reference to rigid anatomical bony structures can be identified relative to a CT base model of the anatomy. These procedures include unicondylar knee replacement and/or patellofemoral knee replacement.
  • Model / Serial
    Serial Numbers: ROB031 through ROB068.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution
  • Product Description
    200996-Cable Assembly, Hybrid Extended Length, || 200997 Cable Assembly, Hybrid, Guidance Module, || 200998 Cable Assembly, Hybrid, UI Panel || Subcomponents for the 203000 RIO STANDARD SYSTEM || Manufactured by: MAKO Surgical, Corp. Fort Lauderdale, FL. || All three cables are integral components and are not purchased separately. || However, 200996-Cable Assembly is the only cable visible. This cable is labeled: 200996-REV-1, KSM 390634-1, SN 000001. 200997 and 200998 Cable Assembly are not visible . || The Tactile Guidance System v2.0 is intended to assist the surgeon in providing software defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures.
  • Model / Serial
    Femoral Tray - Model 0150ARR00001, Lot Number/Quantity: 0609038 (6), 06051107 (4), 01010806 (4), 09010108 (2), 06040707-01 (1), 01010107 (3), 01010607 (1), 01010106 (1) and 06040707 (2) and    Tibial Tray - Model 0150ARR00002, Lot Number/Quantity: 06060308 (6), 06061107 (7), 01020866 (2), 01010507 (1), 01020806 (1), 01020107 (3), 09081107 (2) and 01020607 (2).
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution USA including states of FL, NY, CA, TX, GA, TN, NC and PA.
  • Product Description
    Tibial Array and Femoral Array. || Model Number(s): 0150ARR00001 and 0150ARR00002. || Manufactured by: MAKO Surgical, Corp. || The devices are accessories used with MAKO's Tactile Guidance System (TGS). The Tactile Guidance System is intended to assist the surgeon in providing software defined spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures.
  • Model / Serial
    All Lot codes
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide - US Nationwide Distribution in the states of AK, AL, AR, AZ, CA, CO, CT, FL, GA, HI, GA, IA, ID, IL, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA, WI and WY and the countries of Australia, Taiwan, China, Taiwan, Hong Kong, Greece, United Kingdom, England, Netherlands, Luxembourg, Ireland, Italy, Germany, India, Japan, Korea, Singapore, Thailand, Vietnam, South Africa, and Turkey
  • Product Description
    Total Hip Application (THA) || Product Usage: || The Robotic Arm Interactive Orthopedic System (RIO) is intended to assist the surgeon in providing software define spatial boundaries for orientation and reference information to anatomical structures during orthopedic procedures.
6 more

3 manufacturers with a similar name

Learn more about the data here

  • Manufacturer Address
    Mako Surgical Corporation, 2555 Davie Rd Ste 110, Plantation FL 33317-7424
  • Manufacturer Parent Company (2017)
  • Source
    USFDA
  • Manufacturer Parent Company (2017)
  • Source
    BAM
  • Manufacturer Parent Company (2017)
  • Source
    SATP