Recall of TERUMO 3T L. V. Control Valve

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Terumo Cardiovascular Systems Corp.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    59704
  • Event Risk Class
    Class 2
  • Event Number
    Z-3242-2011
  • Event Initiated Date
    2011-08-11
  • Event Date Posted
    2011-09-16
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-03-20
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Cardiovascular, Cpb Check Valve, Retrograde Flow, In-line - Product Code MJJ
  • Reason
    3-t medical systems one way vent valves, included in the custom terumo cardiovascular kits, may separate at the bond that holds the two halves.
  • Action
    Terumo Cardiovascular Systems initiated contact on August 12, 2011 by phone, fax, email and Urgent: Medical Device Recall mail to all affected customers. The firm advised customers of the affected product, problem and required recall actions. Customers can remove whole customized packs that are not in urgent medical need and return packs. Or the User may opt to use a sterile LH 130 vent valve from Terumo Cardiovascular Systems. A response form was included to return back to the firm. For questions on this recall contact Terumo Customer Service at (734) 525-9580.

Device

  • Model / Serial
    Lot Numbers:  ME19 MG14 MH19
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution, including the states of FL and MI.
  • Product Description
    Cardiovascular Custom Procedure Kits, REV : 2, REV: 4 || FX, CP50,CENT Pack || Item Number: 73386 || Terumo Cardiovascular Systems, Ashland, MA 01721 || The Cardiovascular Procedure Kits are indicated for use only in the extracorporeal circuit for the cardiopulmonary bypass procedure(s) for which the user designed it. The 3-T L. V. Control Valve is a one-way vent valve used during cardiopulmonary bypass surgery to help prevent the buildup of excess vacuum pressure when suctioning either from the heart or the surgical field, and to help prevent inadvertent retrograde now and air into the heart.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Terumo Cardiovascular Systems Corp, 28 Howe St, Ashland MA 01721-1305
  • Manufacturer Parent Company (2017)
  • Source
    USFDA