Recall of Synthes Titanium Trochanteric Fixation Nail (TFN)Helical Blade

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Synthes USA HQ, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    66552
  • Event Risk Class
    Class 2
  • Event Number
    Z-0369-2014
  • Event Initiated Date
    2013-10-03
  • Event Date Posted
    2013-11-20
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2016-08-18
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Rod, fixation, intramedullary and accessories - Product Code HSB
  • Reason
    A potential exists for non conforming synthes titanium trochanteric fixation nail (tfn)-helical blades to be distributed.
  • Action
    Synthes sent a Field Safety Notice dated October 3, 2013, to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to review the options provided in the Field Safety Notice to clarify and mitigate the potential risk. Customers were asked to prepare a list of the affected part and lot numbers and contact the Complaint Unit at 610-719-5596 to receive a Return Authorization Number. Complete and return the Verification Form with the product and Return Authorization number. Customers were also asked to forward the Field Safety Notice to anyone in their facility that needs to be informed. Customers were asked to maintain a copy of the Field Safety Notice. Customers with questions were asked to call 610-719-5450 or contact their Synthes Sales Consultant. For questions regarding this recall call 610-719-5000.

Device

  • Model / Serial
    part nos. 456.300-456.310 & 456.650, 456.300S-456.310S & 456.650S, with lot nos. 5615864 through 7423581
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide Distribution - USA (nationwide) and Internationally to Mexico and Canada.
  • Product Description
    Synthes Titanium Trochanteric Fixation Nail (TFN)-Helical Blade || Synthes Titanium Trochanteric Fixation Nail (TFN)-Helical Blade is used to treat stable and unstable fractures of the proximal femur including pertrochanteric fractures, intertrochanteric fractures, basal neck fractures, and combinations thereof. The long TFN is additionally indicated for subtrochanteric fractures, pertrochanteric fractures associated with shaft fractures, pathologic fractures (including prophylactic use) in both trochanteric and diaphyseal regions, long subtrochanteric fractures, proximal or distal non-unions, malunions, and revisions.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Synthes USA HQ, Inc., 1302 Wrights Ln E, West Chester PA 19380-3417
  • Manufacturer Parent Company (2017)
  • Source
    USFDA