Recall of Synthes TI MIRS Locking Cap, OneStep Titanium Alloy, Part Number 04.631.502

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Synthes USA HQ, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    63230
  • Event Risk Class
    Class 2
  • Event Number
    Z-0396-2014
  • Event Initiated Date
    2012-09-07
  • Event Date Posted
    2013-11-26
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2015-12-18
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Orthosis, spinal pedicle fixation, for degenerative disc disease - Product Code NKB
  • Reason
    This action is being initiated following a detailed investigation in response to reported complaints of post-operative locking cap loosening. synthes has concluded that if the construct is mis-aligned during final tightening, the potential exists for locking caps to loosen post-operatively in certain situations.
  • Action
    Synthes sent an Urgent: Medical Device Product Removal letter on September 7, 2012, to all affected consignees. Consignees were requested to immediately cease using the product, examine their inventory and remove the parts from inventory. If they had the parts, they were further instructed to call Synthes at 1-800-479-6329 to obtain a Return Authorization Number, complete the verification section at the end of the letter and return the verification form. If they did not have the parts, they were requested to complete the verification section at the end of the letter and return the verification form. Consignees with questions were instructed to call 610-719-5450. For questions regarding this recall call 610-719-5000.

Device

  • Model / Serial
    All lots
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Nationwide Distribution including CA, CO, CT, FL, GA, ID, IL, IN, LA, MA, MD, MI, MN, MT, NC, NJ, NY, OH, OR, PA, SC, TN, TX, UT, VA, WA, and WI.
  • Product Description
    Synthes Titanium Minimally Invasive Reduction Screw System Locking Cap, Part Number 04.631.502 || Non-cervical spinal fixation devices intended for posterior pedicle screw fixation, posterior hook fixation, or anterolateral fixation.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Synthes USA HQ, Inc., 1302 Wrights Ln E, West Chester PA 19380-3417
  • Manufacturer Parent Company (2017)
  • Source
    USFDA