Recall of SureSigns

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Philips Electronics North America Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    78733
  • Event Risk Class
    Class 3
  • Event Number
    Z-0268-2018
  • Event Initiated Date
    2017-09-20
  • Event Date Posted
    2017-12-20
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Monitor, physiological, patient(with arrhythmia detection or alarms) - Product Code MHX
  • Reason
    Some suresigns vsi, vs2+ products have the date of manufacture on its serial number label as %dom , instead of the specific date in the format of yyyy-mm.
  • Action
    Philips sent each known affected customer a Field Safety Notice, dated September, 2017. The Field Safety Notice informs customers of the issue, identifies details of the units affected, gives instructions on actions to be taken by the customer and identifies what action Philips plans to take to remedy the issue. Philips will provide a corrected label free of charge

Device

  • Model / Serial
    SureSigns VSi : 863275, 863276, 863277 SureSigns VS2+ : 863278, 863279
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide distribution. Australia, Austria, Bahrain, Belgium, Brazil, Denmark, France, French Polynesia, Germany, Hong Kong, India, Ireland, Israel, Italy, Kenya, Lebanon, Lesotho, Malaysia, Maldives, Morocco, Netherlands, Oman, Pakistan, Palestine, Poland, Saudi Arabia, South Africa, Spain, Sweden, Thailand, Turkey, United Kingdom, UAE, Vietnam, and Zimbabwe.
  • Product Description
    Philips SureSigns VSi / SureSigns VS2+ vital signs monitor used in healthcare environments and transport within a facility.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Philips Electronics North America Corporation, 3000 Minuteman Rd, Andover MA 01810-1032
  • Manufacturer Parent Company (2017)
  • Source
    USFDA