Recall of Smith & Nephew

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Smith & Nephew, Inc. Endoscopy Division.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    57041
  • Event Risk Class
    Class 2
  • Event Number
    Z-0421-2011
  • Event Initiated Date
    2010-10-14
  • Event Date Posted
    2010-11-18
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-05-09
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Nonabsorbable Polyethylene Synthetic Suture - Product Code GAT
  • Reason
    Fast-fix 360 needle delivery system may not allow the t-2 (anchor) to advance for implantation.
  • Action
    Smith & Nephew notified customers by an Urgent - Product Recall 1st Notification - Urgent letter sent via Federal Express October 14, 2010. The letter identified the affected product and explained the problem. The letter asked customers to call for a Return Authorization (RA) Number. Customers are to complete the form and return of the affected product along with a copy of the letter to the address provided being sure to reference the RA number. Questions were to be directed to Cindy Burns at 508-261-3655. Consignees out side the US were notified by e-mail.

Device

  • Model / Serial
    Lot Numbers: 50327272, 50327427, 50327430, and 50328898.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide Distribution - USA, Dubai, and Great Britain.
  • Product Description
    Smith & Nephew FAST FIX 360, REVERSE CURVED NEEDLE || Catalog Number; 72202469. || Intended for use as a suture retention device to facilitate percutaneous or endoscopic soft tissue procedures such as shoulder stabilization (Bankart Repair), rotator cuff repair, meniscal repair, and gastrostomy.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Smith & Nephew, Inc. Endoscopy Division, 150 Minuteman Drive, Andover MA 01810-1031
  • Source
    USFDA