Recall of Roche Molecular Diagnostics Inc.

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Roche Molecular Systems, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    74221
  • Event Risk Class
    Class 2
  • Event Number
    Z-2254-2016
  • Event Initiated Date
    2016-04-05
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-12-11
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Somatic gene mutation detection system - Product Code OWD
  • Reason
    During internal studies using contrived plasma specimens, several mutations (l8568r, exon 19 deletion, t790m) inconsistently generated "no mutation detected" (ie false negative ) result with the cobas egfr mutation text v2.0 when utilizing the cobas cfdna sample preparation kit.
  • Action
    Roche Molecular Diagnostics sent an Urgent Field Safety Notice letter dated April 5, 2016 to affected customers. Then letter identified the affected product, problem and actions to be taken. The Instructions for use are provided for the user until new ones are available..

Device

  • Model / Serial
    Lot W08792, Lot W11783, Lot W11438, Lot W14903, Lot W05108. Lot W11435, Lot W12238
  • Product Classification
  • Device Class
    3
  • Implanted device?
    No
  • Distribution
    Foriegn Distribution Austria, Belgium, Croatia, Czech Republic, Denmark, France, Germany, Greece, Hungary , Italy, Lithuania, Luxembourg, Netherlands, Norway, Poland, Romania, Slovakia, Slovenia, Spain, Switzerland, Turkey, United Kingdom cfDNA: Austria, Belgium, Croatia, Czech Republic, Denmark, France, Germany, Greece, Hungary , Italy, Lithuania, Luxembourg, Netherlands, Poland, Romania, Slovakia, Slovenia, Spain, Switzerland, Turkey, United Kingdom
  • Product Description
    cobas EGFR Mutation Test V2 || Materials number || CE-IVD: EGFR v2: 07248563190 || cfDNA: 07247737190 || Device Identifier: || EGFR v2.0: 00875197005448 || cfDNA: 00875197005424 || Product Usage: || A real time PCR Test for the qualitative detection and identifications of mutations n exons 18, 19, 20 and 21 of the epidermal growth factor receptor (EGFR) gene in DNA derived from formalin-fixed paraffin-embedded (FFPET) tumor tissue or plasma from non-small cell lung cancer (NSCLC) patients. The test also is intended to be used as an aid in selecting patients with NSCLC for therapy with an EGFR tyrosine kinase inhibitor (TKI).
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Roche Molecular Systems, Inc., 1080 US Highway 202 S, Branchburg NJ 08876-3733
  • Manufacturer Parent Company (2017)
  • Source
    USFDA