Recall of Newport HT70 Ventilator

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Newport Medical Instruments Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    58619
  • Event Risk Class
    Class 2
  • Event Number
    Z-2406-2011
  • Event Initiated Date
    2010-09-20
  • Event Date Posted
    2011-06-02
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2011-06-03
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Ventilator, continuous facility use. - Product Code CBK
  • Reason
    The recall was initiated because newport medical has confirmed a limited number of power cords recently received from their supplier, glob-tek, have a slightly oversized plug connector which prevents the cord from locking into place. these cords are fully functional as supplied. however, the cord can be easily disconnected. if the cord is disconnected, the ht70 will alert the user with a power di.
  • Action
    Newport Medical sent an PRODUCT NOTICE LETTER, dated September 20, 2011, to all affected customers. The letter identified the product, the problem, and the action needed to be taken by the customer. Customers were instructed to discard the original cord and only use the replacement cord to avoid unintentional disconnection of the power cord. Each affected Customer was sent a replacement cord. Customers with any questions regarding the Product Notice were instructed to contact the Technical Support Department at (800) 451-3111.

Device

  • Model / Serial
    Serial Numbers: N10HT700810209 - N10HT700810218, N10HT700910219-N10HT700910225
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution--USA (nationwide) including the states of MA, PA, OH, IA and Puerto Rico and the countries of Colombia, UAE, Hong Kong, Hungary, India, Japan, Nepal, China, Philippines, Singapore and South Africa.
  • Product Description
    Newport HT70 Ventilator. Model #HT70, || The Newport HT70 ventilator is intended to provide continuous or intermittent positive pressure mechanical ventilatory support for the care of individuals who require mechanical ventilation through invasive or noninvasive interfaces. Specifically, the Newport HT70 ventilator is applicable for infant, pediatric and adult patients greater than or equal to 5 kg (11 Ibs). The Newport HT70 ventilator is suitable for use in hospital, subacute, emergency room, and home care environments as well as for transport and emergency response applications.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Newport Medical Instruments Inc, 1620 Sunflower Ave, Costa Mesa CA 92626-1513
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    USFDA