Recall of Medtronic MiniMed Paradign Insulin Infusion Pumps

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Medtronic MiniMed.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    37944
  • Event Risk Class
    Class 2
  • Event Number
    Z-1007-2007
  • Event Initiated Date
    2007-04-27
  • Event Date Posted
    2007-07-07
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-09-19
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Insulin Infusion Pumps - Product Code LZG
  • Reason
    Exposure to magnetic resonance imaging (mri) has resulted in damage to the component that monitors and controls movement of the motor in the minimed paradigm insulin infusion pump. although there were alarms as a result of the damage, some users cleared these alarms and continued using the pump. under such conditions, the pump will significantly over-deliver; potentially causing severe hypoglycemi.
  • Action
    Firm mailed Medical Device Safety letters on April 24, 2007, to healthcare professionals, existing pump users and MRI facilities reiterating the existing warning in the pump User Guide to avoid exposing the pump to MRI (or similar high strength electromagnetic fields) and strengthening previous warning by specifically mentioning the potential for over-delivery and severe hypoglycemia. Firm is also including an insert with this information with any Paradigm infusion pumps shipped to new customers.

Device

  • Model / Serial
    "All serial numbers" for the following Paradigm models: MMT-51 1, MMT-512, MMT-712, MMT-515, MMT-715, MMT-522 and MMT-722
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide: USA, US Virgin Islands, Antigua, Australia, Austria, Bahamas, Bahrain, Bermuda, Brazil, Canada, Chile, China, Columbia, Czech Republic, Denmark, Dominican Republic, Egypt, France, Germany, Greece, Hong Kong, India, Ireland, Israel, Italy, Japan, Korea, Kuwait, Lebanon, Malaysia, Mexico, Netherlands, New Zealand, Norway, Panama, Poland, Puerto Rico, Qatar, Romania, Saudi Arabia, Singapore, Slovakia, Slovenia, South Africa, Spain, Sweden, Switzerland, Taiwan, Turkey, United Arab Emirates, United Kingdom, Uruguay, Venezuela.
  • Product Description
    Medtronic MiniMed Paradigm Insulin Infusion Pumps for the following Paradigm models: MMT-511, MMT-512, MMT-712, MMT-515, MMT-715, MMT-522 and MMT-722
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Medtronic MiniMed, 18000 Devonshire St, Northridge CA 91325-1219
  • Source
    USFDA