Recall of Leica Ceiling Mount MSF1

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Leica Microsystems, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    66274
  • Event Risk Class
    Class 2
  • Event Number
    Z-1725-2014
  • Event Initiated Date
    2013-09-11
  • Event Date Posted
    2014-06-07
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-04-24
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Micro total analysis instrument system - Product Code OUE
  • Reason
    The ceiling mount supplier encountered an event in which the drive screw in the motor unit, which lifts and lowers the lower lift arm, broke. as a result, the lift arm fell down approx. 60 cm (23.6 inches).
  • Action
    A Medical Device Correction letter, dated September 11, 2013, was sent to all direct accounts. The letters advised customers that a Leica Microsystems representative will contact them and make arrangements to conduct an inspection of the ceiling mount(s) and to provide additional preventative maintenance and inspection protocols for the devices. Customers are asked to complete and return the enclosed Acknowledgement Form and send it back to Leica Microsystems within 10 days of receiving the Medical Device Correction letter. Customers with questions should contact their Leica Microsystems representative.

Device

  • Model / Serial
    Leica Ceiling Mount MSF-1; Article Numbers: 10446781, 10446782
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution -- USA, including the states of AZ, IL, MA, MO, NC, OR, TX, VA, and WI; and, the countries of Australia, Austria, Chile, China, Colombia, Czech Republic, Greece, Israel, Italy, Japan, Malaysia, Netherlands, Norway, Oman, Saudi Arabia, South Korea, Spain, Sweden, Switzerland, and United Kingdom.
  • Product Description
    Leica Ceiling Mount MSF-1 for use with M841 and M501 operating microscopes. Article Number 10446781 utilizes a supply voltage of 230 V. Article Number 10446782 utilizes a supply voltage of 110 V. || Intended to be used for improving the visibility of objects through magnification and illumination.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Leica Microsystems, Inc., 1700 Leider Ln, Buffalo Grove IL 60089-6622
  • Manufacturer Parent Company (2017)
  • Source
    USFDA