Recall of FOCAL Workstation

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Elekta, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    68984
  • Event Risk Class
    Class 2
  • Event Number
    Z-2574-2014
  • Event Initiated Date
    2014-08-18
  • Event Date Posted
    2014-09-03
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-08-08
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    System,planning,radiation therapy treatment - Product Code MUJ
  • Reason
    When dicom is exporting an arc plan (vmat, dynamic conformal of 3d static arcs) and using the composite field sequencing (cfs) feature, the dicom exported plan will not match the approved treatment plan.
  • Action
    Elekta, Inc. issued an Urgent Important Field Safety Notice letter (IFSN 382-01-MON-001) to all affected customers.. Confirmation of receipt is to be completed by October 31, 2014. The problem will be resolved in a patch to Focal 4.80. Development is underway with a release date of September 2014 with confirmation of installation of the patch for the fix no later than 6 months from release of the patch. An updated notice from the manufacturer is also being sent to affected customers (FCO: 382-01-MON-001 VID:2.0). For questions contact your local Elekta office.

Device

  • Model / Serial
    Software versions 4.70.00 & 4.80.00
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US (nationwide)in the states of AK, CA, FL, MI, MN, MO, NJ, NY, NC, OH, PA, TN, VA,WA and Puerto Rico, Algeria, Antigua & Barbuda, Australia, Austria, Bahrain, Belarus, Brazil, Bulgaria, Canada, Chile, China, Colombia, Cyprus, Czech republic, Ecuador, Egypt, Estonia, France, Germany, Greece, India, Iraq, Israel, Italy, Japan, Kazakhstan, Malaysia, Malta, Mexico, Morocco, Netherlands, New Zealand, Pakistan Portugal, Romania, Russia, Saudi Arabia, Singapore, Solvenia, South Africa, South Korea, Spain, Switzerland, Thailand, Turkey, and United Kingdom
  • Product Description
    FOCAL Sim Workstation, Radiation Treatment Planning System. || Used for patient contouring and viewing of treatment plan outputs. Also able to perform CT simulations and forward their information to the RTP System for dose calculation.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Elekta, Inc., 400 Perimeter Center Ter Ne, Ste 50, Atlanta GA 30346-1227