Recall of Dimension Gentamicin Flex reagent cartridge

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Siemens Healthcare Diagnostics, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    80009
  • Event Risk Class
    Class 2
  • Event Number
    Z-2181-2018
  • Event Initiated Date
    2018-04-19
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Enzyme immunoassay, gentamicin - Product Code LCD
  • Reason
    The affected lots may exhibit inaccuracy for quality control and patient samples at the low end of the analytical measurement range. the bias is due to the calibration curve not showing separation between the level 1 and level 2 calibrators.
  • Action
    On April 19, 2018, the firm sent an Urgent Medical Device Recall letter to customers. The letter identified the affected lots and advised customers to do the following: Inspect stock, discontinue use of and discard the Dimension and Dimension Vista GENT lots listed in Table 1. ¿ Please review this letter with your Medical Director. ¿ Review your inventory of these products to determine your laboratorys replacement needs and to provide information to Siemens for reporting to the regulatory authorities. ¿ Complete and return the Field Correction Effectiveness Check Form attached to this letter within 30 days. ¿ If you have received any complaints of illness or adverse events associated with the product listed in Table 1, immediately contact your local Siemens Customer Care Center or your local Siemens Technical Support Representative.

Device

  • Model / Serial
    Lots EB8115 BB8159 FB8275
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide distribution. Foreign distribution to Argentina, Australia, Brazil, Bahamas, Canada, Germany, India, Japan, Myanmar, New Zealand, Saudi Arabia, Taiwan, and South Africa.
  • Product Description
    Dimension Gentamicin Flex reagent cartridge, DM GENT, gentamicin enzyme immunoassay, Lot numbers affected are EB8115, BB8159, and FB8275.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Siemens Healthcare Diagnostics, Inc., 500 Gbc Dr Ms 514, Po Box 6101, Newark DE 19702-2466
  • Manufacturer Parent Company (2017)
  • Source
    USFDA