Recall of Device Recall VITROS Immunodiagnostic Products Estradiol Reagent Pack

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by ORTHO-CLINICAL DIAGNOSTICS.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    74764
  • Event Risk Class
    Class 2
  • Event Number
    Z-2352-2016
  • Event Initiated Date
    2016-07-14
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2018-06-08
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Radioimmunoassay, estradiol - Product Code CHP
  • Reason
    Ortho clinical diagnostics has issued a recall of their vitros immunodiagnostics estradiol reagent assay. the firm was made aware of a potential cross-reactivity between the drug fulvestrant and thevitros immunodiagnostic estradiol reagent assay. the firm conducted an internal investigation and was able to confirm biased positive (ranging from 1303-4046%) on estradiol results, obtained from postmenopausal females taking fulvestrant.
  • Action
    On 7/14/2016, URGENT PRODUCT CORRECTION NOTIFICATION Customer Letter (Ref. CL2016-141, dated 7/14/2016) was sent via FedEx overnight courier and/ or ORTHO PLUS e-Communications and/ or US Postal Service Priority Mail (for PO Boxes only) to all customers who received product since 6/1/2015 to inform them that Fulvestrant is an interferent of the Estradiol Reagent Pack and causes positively biased results. Discuss any concerns you may have regarding previously reported estradiol results with your Laboratory Medical Director to determine the appropriate course of action. The results from this or any other diagnostic test should be used and interpreted only within the context of the overall clinical picture. For questions, contact Customer Technical Services at 1-800-421-3311. Foreign affiliates were informed of the issue via e-mail on 7/14/2016 and instructed to notify their consignees of the issue.

Device

  • Model / Serial
    Lot numbers: 1470 (expiry date 02-Aug-16); 1480 (expiry date 05-Aug-16), 1490 (expiry date 10-Oct-16), 1500 (expiry date 10-Oct-16), 1510 (expiry date 01-Nov-16), 1528 (expiry date 01-Nov-16) 1538 (expiry date 14-Mar-17), 1548 (expiry date 09-Mar-17), 1558 (expiry date 09-Mar-17) and 1568 (expiry date 29-Mar-17)
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Nationwide, Puerto Rico, and foreign distribution to the following countries: Australia, Brazil, Canada, Chile, China, Colombia, England, France, Germany, India, Italy, Japan, Mexico, Panama, Poland, Singapore, Spain, Venezuela.
  • Product Description
    VITROS Immunodiagnostic Products Estradiol Reagent Pack, Unique Device Identifier No. 10758750005017, REF/Catalog Number/Product Code 855 2630; IVD -- Ortho-Clinical Diagnostics, Pencoed, Bridgend CF35 5PZ, UK --- The VITROS Estradiol test is performed using the VITROS Estradiol Reagent Pack and Calibrators on VITROS ECi/ECiQ Immunodiagnostic Systems, VITROS 3600 Immunodiagnostic Systems and VITROS 5600 Integrated Systems.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    ORTHO-CLINICAL DIAGNOSTICS, FELINDRE MEADOWS, Bridgend United Kingdom
  • Manufacturer Parent Company (2017)
  • Source
    USFDA