Recall of Device Recall VERTIER Surgical Table

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Stryker Communications Corp.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    49021
  • Event Risk Class
    Class 2
  • Event Number
    Z-2379-2008
  • Event Initiated Date
    2008-07-02
  • Event Date Posted
    2008-09-18
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2010-01-07
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Operating-Room Table - Product Code FQO
  • Reason
    Hydraulic lines responsible for tilting the surgical table have the potential to be severed when articulating table to its lowest position, possibly resulting in the unexpected and rapid movement of the table.
  • Action
    Urgent: Device Recall letters were sent to consignees on 07/02/08 via FedEx with return receipt. Consignees were asked to discontinue use of the tables until a Stryker representative has come to the facility and updated the table. The firm has identified and validated replacement parts that prevent this occurrence.

Device

  • Model / Serial
    All lot codes/serial numbers.
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution --- including states of AR, CA, FL, GA, ID, IL, IN, KS, KY, MN, MO, ND, NJ, NY, OH, OK, OR, SD, TX, UT, VA and Washington DC.
  • Product Description
    VERTIER Surgical Table, Catalog #0788-100-001S (SIDNE-enabled standard table with 5th wheel); distributed by Stryker Communications, Flower Mound, TX. || Is an AC powered, general purpose, mobile surgical table with electro-hydraulically controlled movements which are part of a control feedback system.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Stryker Communications Corp, 1410 Lakeside Pkwy Ste 100, Flower Mound TX 75028-4026
  • Manufacturer Parent Company (2017)
  • Source
    USFDA