Recall of Device Recall UniCel DxI 600 Access Immunoassay

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Beckman Coulter Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    57952
  • Event Risk Class
    Class 2
  • Event Number
    Z-1939-2011
  • Event Initiated Date
    2011-01-26
  • Event Date Posted
    2011-04-11
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-06-04
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Analyzer, chemistry (photometric, discrete), for clinical use - Product Code JJE
  • Reason
    The recall was initiated due to beckman coulter receiving a report of results that were associated with incorrect patient identifications when two sample racks advanced into the sample presentation area in one push. the first rack of the two was not scanned. this is referred to as a "pushed pair." if a pushed pair event occurs, results may be associated with the incorrect patient identification.
  • Action
    Beckman Coulter sent an Urgent: Field Safety Notice Product Correction letter dated January 26, 2011, via US Postal Service to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were instructed to: 1. To prevent a pushed pair, be sure your sample racks are free of debris prior to use. Do not apply additional labels to the sample racks. Extra labels can obscure the edges of a sample rack, or obstruct the gap between two racks. Be sure sample labels do not extend beyond the edges of a sample rack; 2. If a pushed pair occurs on the UniCel DxI system, the system generates a yellow Event Log message - Clear the presentation tray and press ROUTINE button. This Event Log message is associated with a variety of common Sample Presentation Unit (SPU) errors. For that reason, you must review the Event Log details to confirm the pushed pair event has not occurred; 3. Detach the Appendix included with this notification and store it near your UniCel DxI system. Use the Appendix as a reference if you suspect a pushed pair event has occurred on your system. Beckman Coulter also requested their customers share the recall information with their laboratory staff, and retain pages 1 and 2 of this notification as part of your laboratory Quality System documentation. For questions regarding ththe recall notification, customers were instructed to contact Beckman Coulter Customer Support Center on the Beckman Coulter website at http://www.beckmancoulter.com/customersupport/support, or call 1-800-854-3633 in the United States or Canada. Outside the United States and Canada, contact their local Beckman Coulter Representative.

Device

  • Model / Serial
    DxI System Software versions: 2.3, 2.4, 4.1, 4.2.1, 4.3 (Current released version), 4.3.2 (Released to a single Japanese customer only)
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - USA (nationwide) and the countries of Algeria, Angola, Australia, Austria, Belgium, Brazil, Bulgaria, Canada, China, Colombia, Croatia, Czech Republic, Denmark, Finland, France, French Polynesia, Germany, Greece, Hong Kong, Hungary, India, Ireland, Israel, Italy, Japan, Jordan, Republic of Korea, Kuwait, Liechtenstein, Malaysia, Mayotte, Mexico, Morocco, Namibia, Netherlands, New Zealand, Norway, Philippines, Poland, Puerto Rico, Romania, Russian Federation, Singapore, Slovakia, South Africa, Spain, Swaziland, Sweden, Switzerland, Taiwan, Thailand, Tunisia, Turkey, United Arab Emirates, United Kingdom, Venezuela, and Vietnam.
  • Product Description
    UniCel DxI 600 Access Immunoassay || Systems; Part Number(s): DxI 600: A30260, DxI 600 with spot B A71460 || The DxI Immunoassay System is an in vitro diagnostic device used for the quantitative, semi-quantitative or qualitative determination of various analyte concentrations found in human body fluids.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Beckman Coulter Inc., 200 S Kraemer Blvd, Brea CA 92821-6208
  • Manufacturer Parent Company (2017)
  • Source
    USFDA