Recall of Device Recall TruVidia Wireless Camera System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Trumpf Medical Systems, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    79336
  • Event Risk Class
    Class 2
  • Event Number
    Z-0824-2018
  • Event Initiated Date
    2017-12-15
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Camera, television, surgical, without audio - Product Code FWB
  • Reason
    The radiated emission from the truvidia" wireless receiver is above the normative accepted limits, in which the radiated emission may interact with other devices in the operating room and cause them not to function properly.
  • Action
    Trumpf Medical Systems sent an Urgent Medical Device Correction letter dated December 15, 2017. Instructions include to complete and return the Confirmation of Receipt, arrange for the Trumpf Medical Engineer or an authorized Service Engineer to upgrade the affected device, and ensure that all users of the device are aware of the recall. For further questions, please call (843) 329-0543

Device

  • Model / Serial
    Catalog Number 1940747, All serial numbers: 102584474, 102584475, 102584477, 102584478, 102805330, 102813656, 102813657, 102813658, 102813659, 102813660, 102813661, 102813662, 102860647, 102860652, 102863706, 102863707, 102867783, 102867784, 102925734, 102925735, 102925736, 102925737, 102925738, 102925739, 102925740, 102925741, 102925742, 102925743, 102928703, 102932185, 102932186, 102932187, 102932188, 102932189, 102932203, 102932204, 102932205, 102932206, 102932207, 102932208, 102932209, 102932210, 102932211, 102932212, 102932217, 102932218, 102932219, 102932220, 102932221, 102932223, 102934525, 102934526, 102934527, 102934528, 102934529, 102936117, 102939484, 102940382, 102940383, 102940384, 102940386, 102940387, 102940388, 102940389, 102940390, 102940391, 102940408, 102940409, 102940410, 102961390, 102961391, 102961392, 102961393, 102961394, 102961395, 102961396, 102961397, 102961398, 102961399, 102961400, 102961401, 102975336, 102986494, 102986495, 102988480, 102989096, 102989607, 102989608, 102989615, 102990285, 102990286, 102994502, 102994503, 102994504, 102994505, 102994506, 102994525, 102994526, 102994529, 102994530, 102996306, 103005879, 103005880, 103005889, 103005890, 103005891, 103005892, 103005893, 103006636, 103010023, 103010759, 103010760, 103010761, 103010762, 103010763, 103012786, 103012787, 103013644, 103017040, 103017041, 103019900, 103020713, 103022348, 103022349, 103022350, 103022351, 103022352, 103022794, 103024049, 103024050, 103030284, 103031623, 103034106, 103034109, 103038842, 103038843, 103038844, 103038845, 103038846, 103038847, 103038848, 103038849, 103038850, 103038853, 103038854, 103038855, 103038856, 103038857, 103038858, 103038859, 103038860, 103038861, 103038862, 103038863, 103038864, 103038865, 103038866, 103039468, 103042319, 103042320, 103042321, 103042322, 103042925, 103042926, 103046119, 103046120, 103046121, 103046122, 103046123, 103046124, 103046125, 103046126, 103046127, 103046128, 103046129, 103046130, 103048248, 103065061, 103070795, 103070796, 103070797, 103070798, 103079001, 103079053, 103087365, 103087366, 103087367, 103087368, 103087369, 103087370, 103087371, 103090135, 103090136, 103090137, 103091507, 103091508, 103091509, 103091510, 103091511, 103095664, 103101676, 103101826, 103101864, 103101886, 103103841, 103103842, 103103843, 103103844, 103103845, 103104556, 103113059, 103117961, 103118986, 103118987, 103118988, 103118989, 103118990, 103118991, 103118992, 103118993, 103118994, 103118995, 103123759, 103133224, 103134656, 103138822, 103143214, 103149993, 103164298, 103168053, 103168341, 103168431, 103176559, 103176571, 103176574, 103191728, 103191729, 103194419, 103214005, 103214022.
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US Distribution to the states of : GA, IL, IN, PA, SC, TX, UT, VA. and to the countries of : Austria, Australia, Bangladesh, Belgium, France, Switzerland, Czech Republic, Germany, Denmark, Spain, United Arab Emirates, United Kingdom, Ireland, Italy, Kuwait, Lithuania, Poland, Portugal, Romania, Sweden, Slovenia, Thailand, Turkey.
  • Product Description
    Camera System, Television, Surgical without audio || Intended for transmission and documentation of surgical interventions for the purpose of archiving and teaching.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Trumpf Medical Systems, Inc., 1046 Legrand Blvd, Charleston SC 29492-7672
  • Manufacturer Parent Company (2017)
  • Source
    USFDA