Recall of Device Recall Terumo Coronary Ostia Cannulae

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Terumo Cardiovascular Systems Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    58762
  • Event Risk Class
    Class 1
  • Event Number
    Z-2554-2011
  • Event Initiated Date
    2011-05-16
  • Event Date Posted
    2011-06-14
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-03-21
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter, cannula and tubing, vascular, cardiopulmonary bypass - Product Code DWF
  • Reason
    Terumo has discovered several instances of adhesive build-up and or skiving of plastic (plastic flash) inside the distal tip of the terumo coronary ostia cannula. the defect was discovered during in-house inspection after terumo cvs implemented a new inspection process for the cannula. there have been no reports of the defect in clinical use.
  • Action
    Terumo Cardiovascular Systems Corporation sent an URGENT MEDICAL DEVICE REMOVAL notice dated May 16, 2011, to all affected customers. The notice identified the product, the problem, and the action to be taken. The letter described the problem, the potiential hazard, and the action to be taken by the consignee. Consignees were instructed to discontinue use of the product and return all product to Terumo. The letter provided a list of alternate products to be used instead of the recalled products. Consignees with questions should call 1-800-521-2818 Monday through Friday 8AM to 6PM.

Device

  • Model / Serial
    Part Number 804115 lot 0520497, 0528973, 0569610, 0606841.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - USA (nationwide) and the countries of BELGIUM, BRAZIL, DOMINICAN REPUBLIC, UNITED ARAB EMIRATES (UAE), SINGAPORE, MALAYSIA, AND SOUTH AFRICA.
  • Product Description
    804115, Terumo Coronary Ostia cannula, 10 Fr, 10 (25 cm) long || A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to cannulate the vessels, perfuse the coronary arteries, and to interconnect the catheters and cannulas with an oxygenator. The device includes accessory bypass equipment.