Recall of Device Recall Terumo Advanced Perfusion System 1

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Terumo Cardiovascular Systems Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    57416
  • Event Risk Class
    Class 2
  • Event Number
    Z-0882-2011
  • Event Initiated Date
    2010-12-02
  • Event Date Posted
    2011-01-07
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-04-17
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Console, heart-lung machine, cardiopulmonary bypass - Product Code DTQ
  • Reason
    The firm identified that a component within the system 1 abd and occluder modules that may malfunction. the air bubble detector module (abd) is used with an air sensor to detect gross air bubbles in the perfusion circuit. the occluder module is used with the occluder head to provide a computer controlled tube clamping mechanism to regulate the flow in the venous line. the firm identified a fai.
  • Action
    Terumo Cardiovascular Systems Corporation issued an URGENT MEDICAL DEVICE CORRECTION letter dated 12/2/2010 to the Director of Cardiac Operating Room Services or Operating Room Nurse Manager. The letter identified the product, the problem, and the action to be taken. The letter stated the firm will replace all modules in the affected population, and that a representative would contact the consignee regarding the replacement schedule. Customers were to review the Medical Device Correction. Assure that all user were aware of the notice. Confirm receipt of the communication by faxing the attached Customer Response Form to the fax number indicated on the form. For questions regarding this recall call 1-800-521-2818.

Device

  • Model / Serial
    01198, 01205-01241, 01243-01281, 01283-01399, 01401-01404, 01406-01422, 01424-01433, 01435-01554, 01556-01564, 01565-01581, 01583-01609, 01611, 01613-01660, 01662-01721, 01724-01725.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US, Austrailia, Belgium, Canada, Chile, Columbia, Costa Rica, Dominican Republic, Guatamala, Hong Kong, Indonesia, Japan, Korea, Malaysia, Mexico, Phillipines, Saudi Arabia, Singapore, Taiwan, Thailand, United Arab Emirates, and Vietnam
  • Product Description
    Air bubble detect module, catalog 802110, Terumo Cardiovascular System Corp, Ann Arbor, MI. || The air bubble detect module is used with an air sensor to detect gross air bubbles in the perfusion circuit.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Terumo Cardiovascular Systems Corporation, 6200 Jackson Road, Ann Arbor MI 48103-9586
  • Manufacturer Parent Company (2017)
  • Source
    USFDA