Recall of Device Recall Terumo Advanced Perfusion System 1

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Terumo Cardiovascular Systems Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    50554
  • Event Risk Class
    Class 2
  • Event Number
    Z-0909-2009
  • Event Initiated Date
    2008-11-07
  • Event Date Posted
    2009-02-24
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2009-07-07
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Console, heart-lung machine, cardiopulmonary bypass - Product Code DTQ
  • Reason
    The power manager board may cause a short circuit, resulting in loss of system power, loss of central control monitor or electrical arcing.
  • Action
    An "Urgent Medical Device Correction" letter was sent to consignees on November 7, 2008. The letter described the reason for correction and provided instructions to customers. Terumo Cardiovascular Systems Corporation will replace the power manager boards on the affected devices. Customers were instructed to complete and fax the Customer Response Form to CVS Customer Service at 1-800-292-6551 (US only) or respond by telephone at 1-800-521-2818. Please direct questions to CVS Customers Service at 1-800-521-2818.

Device

  • Model / Serial
    Serial Numbers: 0011 through 0610, 1001 through 1034, 1037 through 1049, 1100 and 1103 through 1174.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution including USA and countries of Australia, Belgium, Canada, Columbia, Costa Rica, Dominican Republic, Egypt, Germany, Honduras, Hong Kong, India, Indonesia, Israel, Japan, Jordan, Kuwait, Malaysia, Mexico, Pakistan, Philippines, Russia, Saudi Arabia, Singapore, South Africa, South Korea, Taiwan, Thailand, Turkey, United Arab Emirates and Viet Nam.
  • Product Description
    Terumo Advanced Perfusion System 1; 100V -120V, 15 A (circuit breaker), 50/60 Hz (20A power source required) base. Terumo Cardiovascular Systems, Ann Arbor, MI. Model 801763. || The device is indicated for use in the extracorporeal circulation of blood for arterial perfusion and cardiopulmonary bypass procedures by a perfusionist.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Terumo Cardiovascular Systems Corporation, 6200 Jackson Road, Ann Arbor MI 48103-9586
  • Manufacturer Parent Company (2017)
  • Source
    USFDA