Recall of Device Recall TactiSys Quartz Pack, PN004 400

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by St Jude Medical.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    70490
  • Event Risk Class
    Class 2
  • Event Number
    Z-1284-2015
  • Event Initiated Date
    2014-11-25
  • Event Date Posted
    2015-03-17
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2015-05-06
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter, percutaneous, cardiac ablation, for treatment of atrial fibrillation - Product Code OAE
  • Reason
    A configuration update needs to be done on tactisys to appropriately recognize all tacticath catheters.
  • Action
    St. Jude Medical sent a Service Bulletin to inform of a TactiSys Configuration File update that needs to be performed. A technical service personnel will visit each consignee and performed the software change on-site. For questions about this Service Bulletin, contact Technical Support (ETechsupport@sjm.com).

Device

  • Model / Serial
    30078, 30118, 30368, 30059, 30098, 30169, 30110, 30042, 30108, 30066, 30067, 30117, 30172, 30063, 30061, 30060, 30161, 30183, 30129, 30097, 30341, 30043, 30344, 30139, 30112, 30148, 30071, 30096, 30221, 30178, 30204, 30076, 30332, 30343, 30056, 30082, 30123, 30091, 30054, 30087, 30218, 30173, 30143, 30095, 30157, 30176, 30068, 30152, 30158, 30080, 30083, 30153, 30093, 30452, 30121, 30160, 30165, 30088, 30180, 30195, 40000, 30109, 30090, 30147, 30156, 30174, 30124, 30058, 30105, 30070, 30170, 30084, 30333, 30089, 30350, 30222, 30228, 30229, 30134, 30045, 30346, 30177, 30184, 30454, 30111, 30075, 30073, 30219, 30085.
  • Product Classification
  • Device Class
    3
  • Implanted device?
    No
  • Distribution
    US Nationwide Distribution in the states of: AL, AZ, CA, CO, CT, FL, GA, ID, IL IN, KS, LA, MD, MA, MI, MN,MS, NE, NV,NH, NM, NY, NC, OH, OK OR, PA, TN, TX, UT, VA,WA.
  • Product Description
    TactiSys Quartz Pack, PN-004 400. || For percutaneous catheter radiofrequency (RF) ablation of atrial cardiac arrhythmias that allows visualization of the contact force between TactiCath quartz catheter tip and the heart wall. || Product Usage: This device is indicated for use in cardiac electrophysiological mapping and for the treatment of drug refractory recurrent symptomatic paroxysmal atrial fibrillation, when used in conjunction with a compatible radiofrequency generator and three-dimensional mapping system.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    St Jude Medical, 1 Saint Jude Medical Dr, Saint Paul MN 55117-1789
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “We are in constant communication with regulatory agencies and competent authorities worldwide which allows us to implement global recalls or in-country communication quickly and effectively,” Abbott, which now owns St. Jude Medical told ICIJ in a statement. In addition to sending global notices to physicians worldwide, we also make sure that product advisories are available online and classification of product recalls and product advisories are determined by global regulatory bodies which can impact the timing in any given country. MD companies follow varying regulations in different countries. In come countries software is not regulated so a recall in one country related to software would not be classified as a recall or field action in another. In addition, review cycles within the regulatory process can be different in each country which can impact communication and recall timing.
  • Source
    USFDA