Recall of Device Recall Synthes Matrix System T1 Matrix Locking Cap

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Synthes USA (HQ), Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    59290
  • Event Risk Class
    Class 2
  • Event Number
    Z-3207-2011
  • Event Initiated Date
    2011-03-11
  • Event Date Posted
    2011-09-15
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2014-12-18
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Orthosis, spinal pedicle fixation, for degenerative disc disease - Product Code NKB
  • Reason
    Labeling correction -- the locking cap was not able to be loosened, resulting in the breakage of the screwdriver or the rod to be cut and the assembly to be removed (screw, cap, and rod). this poses a potential risk of significant prolongation of or time.
  • Action
    The firm initiated this action on March 11, 2011 by issuing an Urgent: Medical Device Labeling Correction letter to all consignees. The letter identified the affected product and stated the reason for the correction. It also instructed the consignee to review and attach the supplementary technique page to any MATRIX Spine System Technique Guides that they may have had in their facility. Customers are to complete the Verification Section of the letter and return it to the firm via mail, fax, or e-mail. If customers have questions, they can call 610-719-5063 or their Synthes Spine Sales Consultant.

Device

  • Model / Serial
    All lots
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Nationwide Distribution -- AL, AZ, AR, CA, CO, CT, DE, FL, GA, ID, IL, IN, IA, KS, LA, ME, MD, MA, MI, MN, MS, MO, MT, NE, NV, NH, NJ, NM, NY, NC, OH, OK, OR, PA, SC, TN, TX, UT, VA, WA, WV, and WI.
  • Product Description
    Synthes T1 Matrix Locking Cap of the Synthes Matrix System, Part Number 04.632.000. || Intended for posterior pedicle screw fixation, posterior hook fixation, or anterolateral fixation.