Recall of Device Recall syngo Imaging XS

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Siemens Medical Solutions USA, Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    47524
  • Event Risk Class
    Class 2
  • Event Number
    Z-1643-2008
  • Event Initiated Date
    2008-03-10
  • Event Date Posted
    2008-08-24
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2008-11-19
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    System, Image Processing, Radiological - Product Code LLZ
  • Reason
    The firm discovered a problem where the selected patient images on the device may display an additional image from another patient or study.
  • Action
    The recalling firm issued a Customer Safety Advisory via certified mail to affected customers per Update Instructions IM011/08/S. The letter informs customers of the potential issue and provides instructions to detect its occurrence. A software update to correct the issue is already available. A service representative will visit affected sites to install the software update. If you have questions concerning the advisory letter or you did not receive a letter contact Alexander Vogel at +49 (9131) 84-3840 or alexander.vogel@siemens,com and make reference to complaint 08-1KM-0073 date 2008-03-06.

Device

  • Model / Serial
    Model number 7502029. Serial numbers: 9288, 9632, 9633, 9640, 9792, 10412, 10625, 11106, 11942, 12029, 12030, 12031, 12032, 12068, 12211, 12216, 12217, 12222, 12229, 12235, 12276, 12283, 12288, 12543, 12577, 12600, 12610, 12660, 12661, 12062, 12063, 12643, 12739, 12773, 12782, 12783, 12789, 13026, 13027, 13090, 13131, 13147, 13155, 13208, 13241, 13280, 13295, 13296, 13297, 13298, 13299, 13300, 13301, 13302, 13303, 13304, 13305, 13306, 13307, 13308, 13310, 13358, 13370, 13371, 13372, 13400, 13401, 13402, 13403, 13404, 13405, 13406, 13407, 13408, 13409, 13410, 13411, 13412, 13413, 13414, 13415, 13416, 13417, 13418, 13419, 13420, 13421, 13427, 13428, 13429, 13432, 13433, 13434, 13435, 13436, 13437, 13438, 13439, 13440, 13441, 13442, 13443, 13444, 13445, 13446, 13447, 13448, 13449, 13450, 13451, 13452, 13453, 13454, 13455, 13456, 13457, 13458, 13459, 13460, 13461, 13462, 13480, 13490, 13491, 13492, 13493, 13494, 13495, 13496, 13501, 13504, 13505, 13510, 13519, 13520, 13574, 13575, 13576, 13591, 13635, 13636, 13637, 13669, 13670, 13671, 13672, 13673, 13674, 13675, 13676, 13679, 13680, 13681, 13682, 13683, 13684, 13685, 13686, 13687, 13688, 13689, 13690, 13691, 13692, 13693, 13694, 13695, 13696, 13697, 13724, 13725, 13732, 13733, 13734, 13735, 13740, 13745, 13749, 13751, 13785, 13791, 13792, 13794, 13811, 13820, 13821, 13822, 13823, 13824, 13825, 13826, 13846, 13847, 13848, 13849, 13850, 13851, 13889, 13890, 13906, 13907, 13908, 13909, 13912, 13913, 13921, 13922, 13933, 13934, 13945, 13959, 13960, 13961, 13968, 13971, 13979, 13980, 13991, 13992, 13996, 13997, 13998, 13999, 14000, 14004, 14005, 14016, 14017, 14043, 14050, 14051, 14052, 14053, 14054, 14059, and 14066.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    The product was shipped to medical facilities in AL, AZ, CA, CO, CT, FL, GA, IA, KS, KY, MD, MI, MN, MO, NC, ND, NE, NJ, NM, NV, NY, OH, OK, PA, TN, TX, WI, and WV.
  • Product Description
    Syn go Imaging XS is a picture archiving and communication system intended to display, process, read, report, communicate, distribute, store and archive digital radiological images, including digital mammography images.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Siemens Medical Solutions USA, Inc, 51 Valley Stream Pkwy, Malvern PA 19355-1406
  • Manufacturer Parent Company (2017)
  • Source
    USFDA