Recall of Device Recall Stryker Orthopaedics

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Stryker Howmedica Osteonics Corp..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    65902
  • Event Risk Class
    Class 2
  • Event Number
    Z-2130-2013
  • Event Initiated Date
    2013-07-02
  • Event Date Posted
    2013-08-29
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2016-04-27
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Clamp, surgical, general & #38; plastic surgery - Product Code GDJ
  • Reason
    Cracks or fracture of the triathlon tibial alignment ankle clamp, an instrument.
  • Action
    Stryker Orthopaedics sent an Urgent Medical Device Correction letter dated July 2, 2013, to all affected customers. The letter identified the product the problem and the action needed to be taken by t he customers. Customers are advised of the issue, potential hazards and risk mitigation factors. Customers are asked to complete the attached form and fax to 855-251-3635. Any questions should be directed to (201) 972-2100. All letters included a Product Correction Bulletin.

Device

  • Model / Serial
    Catalog #6541-2-609 All lot codes
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution
  • Product Description
    Stryker Howmedica Osteonics Triathlon tibial alignment ankle clamp extramedullary (EM) referencing instrument (Cat. No. 6541-2-609), for use in Total Knee Arthroplasty (TKA) when the surgeon elects to use Stryker's Triathlon Total Knee System in conjunction with EM referencing. Non-Sterile Instrument.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Stryker Howmedica Osteonics Corp., 325 Corporate Dr, Mahwah NJ 07430-2002
  • Manufacturer Parent Company (2017)
  • Source
    USFDA