Recall of Device Recall Stryker LFIT Anatomic V40 Femoral Head

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Stryker Howmedica Osteonics Corp..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    75246
  • Event Risk Class
    Class 2
  • Event Number
    Z-0378-2017
  • Event Initiated Date
    2016-08-29
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-05-02
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Prosthesis, hip, semi-constrained, metal/polymer, cemented - Product Code JDI
  • Reason
    Stryker received several complaints describing incidence of harm secondary to taper lock failure for specific lots of numerous catalog numbers of lfit anatomic cocr v40 femoral heads.
  • Action
    Stryker notified their Branches/Agencies of this recall by e-mail on August 29, 2016 and they were asked to quarantine the affected devices. A Recall Notification Letter and Product Accountability Form was also sent on August 29, 2016 via UPS (with return receipt) to their Branches/Agencies/Hospital Risk Management and Surgeons. On October 11, 2016, Stryker sent an updated recall notification via UPS with return receipt to their affected customers because additional customers and lot numbers were identified.

Device

  • Model / Serial
    Catalog #6260-9-236 - Head Diameter 36 mm, Offset +5, including all lots manufactured from 1/102 - 7/1/10; Catalog #6260-9-240 - Head Diameter 40 mm, Offset +4, including all lots manufactured from 1/1/06 - 3/4/11; Catalog #6260-9-244 - Head Diameter 44 mm, Offset +4, including all lots manufactured from 1/1/06 - 3/4/11; Catalog #6260-9-340 - Head Diameter 40 mm, Offset +8, including all lots manufactured from 1/1/06 - 3/4/11; Catalog #6260-9-440 - Head Diameter 40 mm, Offset +12, including all lots manufactured from 1/1/06 - 3/4/11; Catalog #6260-9-344 - Head Diameter 44 mm, Offset +8, including all lots manufactured from 1/1/07 - 3/4/11 and Catalog #6260-9-444 - Head Diameter 44 mm, Offset +12, including all lots manufactured from 1/1/06 - 3/4/11.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    US Nationwide and Internationally
  • Product Description
    LFIT Anatomic V40 Femoral Head, Low Friction Ion Treatment, Sterile, 36 mm, REF 6260-9-236; Modular components designed to be locked onto a femoral hip stem trunnion during surgery for total hip replacement.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Stryker Howmedica Osteonics Corp., 325 Corporate Dr, Mahwah NJ 07430-2006
  • Manufacturer Parent Company (2017)
  • Source
    USFDA