Recall of Device Recall SteeroCathDx Diagnostic Catheter

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Boston Scientific Corp.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    47388
  • Event Risk Class
    Class 2
  • Event Number
    Z-1618-2008
  • Event Initiated Date
    2008-02-14
  • Event Date Posted
    2008-08-30
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2011-01-08
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Cardiac Catheter - Product Code DRF
  • Reason
    Package sterile barrier may be breached, compromising sterility.
  • Action
    Recall initiated on Feb. 14, 2008, via Urgent Medical Device Recall notification being sent to consignees, along with a reply verification tracking form. If you have questions or need a copy of the recall notification, contact Deborah J. Springer at 1-408-935-4944 or springed@bsci.com.

Device

  • Model / Serial
    Model Numbers M0042027BL0 (Lot#: 0011092878, 0011092882, 0011107097) and M0042028BL0 (Lot#: 0011036506, 0011036507, 0011036585, 0011036586, 0011043535, 0011043537, 0011046910, 0011046913, 0011049772, 0011049773, 0011054879, 0011055000, 0011059409, 0011059410, 0011061991, 0011061992, 0011065023, 0011065024, 0011069509, 0011069510, 0011073729, 0011073730, 0011078604, 0011078605, 0011081318, 0011081445, 0011083742, 0011083743, 0011087354, 0011087355, 0011088108, 0011088109, 0011096360)
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution --- including USA and countries of Saudi Arabia, Spain, Italy, Israel, Denmark, Canada and Australia.
  • Product Description
    Boston Scientific SteeroCath-Dx Diagnostic Catheter, Manufactured by Boston Scientific Corporation, San Jose, CA - Cardiac Catheter
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Boston Scientific Corp, 150 Baytech Drive, San Jose CA 95134
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “We take a patient-first approach to assessing the applicability of every recall and communicate to regulatory bodies in all geographies where the recalled device is sold,” Boston Scientific said in a statement to ICIJ. “We have coordinated several recalls across many countries in a timely manner,” the company said, adding that it complies with all national laws, which can often vary and require different processes for reporting information or taking action on recalls. The company said it uses a rigorous and uniform process to take action on recalls and that “when we initiate a field action (e.g. recall, safety alert), every customer who has received an affected product receives a communication that includes a letter for the physician.”
  • Source
    USFDA