Recall of Device Recall Stat Profile Prime Abg AnalyzerStat Profile Prime CCS AnalyzerNova Stat Profile Prime CCS Analyzer

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Nova Biomedical Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    77532
  • Event Risk Class
    Class 2
  • Event Number
    Z-2732-2017
  • Event Initiated Date
    2017-06-19
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Electrode measurement, blood-gases (pco2, po2) and blood ph - Product Code CHL
  • Reason
    Software- scheduled a-qc analysis could initiate prior to a patient result being released by the operator and result in the pending patient result being overwritten with the a-qc test results.
  • Action
    Nova Biomedical issued Urgent Field Correction Notice on June 19, 2017, to all affected customers. The letter advises users of the problem and Nova Biomedical or an authorized Nova Biomedical representative will schedule a no charge update of your Stat Profile Prime Analyzer software to version VI1.0.883.0. A representative will contact customers to schedule this update. Questions: contact Nova Biomedical Technical Support at 1-800-545-6682, in Canada contact us at 1-800-263-5999, or outside of N. America contact your authorized Nova Biomedical subsidiary or distributor. For questions regarding this recall call 781-647-3700.

Device

  • Model / Serial
    All current software versions
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US (Nationwide) Foreign: Albania Algeria Argentina Australia Austria Bangladesh Benin Bolivia Brazil Canada Chile China Colombia Costa Rica Czech Republic ECUADOR Egypt El Salvador Finland France Germany Ghana Greece Guatemala Guyana Honduras Hong Kong Hungary ICELAND India Iran Israel Italy Ivory Coast Japan Jordan Kenya Korea Latvia Macedonia Malaysia Mexico Nepal Netherlands Nigeria Pakistan Pakistan Palestine Peru Philippines Poland Puerto Rico Republic of Panama Republica Dominicana Russia Saudi Arabia Slovak Republic Slovenia South Africa Sri Lanka Switzerland Taiwan Thailand The Netherlands Trinidad,W.I. Tunisia Turkey UK Uruguay Vietnam
  • Product Description
    Nova Biomedical Stat Profile Prime Analyzer as follows: || PN 52855 Stat Profile Prime ABG Analyzer || PN 53655 Stat Profile Prime ABG Analyzer with Scanner || PN 52856 Stat Profile Prime CCS Analyzer || PN 53656 Stat Profile Prime CCS Analyzer with Scanner || PN 53657 Stat Profile Prime CCS Comp Analyzer with Scanner || PN 52857 Stat Profile Prime CCS Comp Analyzer || Blood Gas/Electrolyte/Metabolite/CO-Oximetry Analyzer
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Nova Biomedical Corporation, 200 Prospect St, Waltham MA 02453-3457
  • Manufacturer Parent Company (2017)
  • Source
    USFDA