Recall of Device Recall SONIMAGE HS1

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Konica Minolta Medical Imaging USA, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    79455
  • Event Risk Class
    Class 2
  • Event Number
    Z-1215-2018
  • Event Initiated Date
    2017-12-04
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    System, imaging, pulsed doppler, ultrasonic - Product Code IYN
  • Reason
    There is a risk of circuit board breakage within the main housing of the ac adapter unit. smoke may be emitted from the ac adapter as a direct result.
  • Action
    Konica Minolta is preparing for the final AC Adapter replacement. Upon receipt of the new AC Adapter, owners of SONIMAGE HSl System will be asked to replace the existing AC Adapter. Additionally, instructions for the return of the current AC Adapter will be provided.

Device

  • Model / Serial
    Serial Numbers (each has "A8AR-" prefix): 00068 00031 00062 00066 00063 00047 00065 00032 00064 00028 00069 00060 00027 00067 00061 00001 00002
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Distributed in the following U.S. states: AL, AZ, CA, CO, CT, FL, GA, HI, IA, IL, IN, KY, LA, MA, MD, MI, MN, MO, MS, NC, NJ, NM, NV, NY, OH, OK, OR, PA, SC, TN, TX, UT, WA, WI and the District of Columbia. Distributed in Canada and Brazil.
  • Product Description
    Sonimage HS1 Ultrasound Kit AC adapter, Product Number: A8AR, UDI: 04560141941588
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Konica Minolta Medical Imaging USA, Inc., 411 Newark Pompton Tpke, Wayne NJ 07470-6657
  • Source
    USFDA