Recall of Device Recall Sequoia Spinal System Surgical Kits

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Abbott Spine.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    46888
  • Event Risk Class
    Class 2
  • Event Number
    Z-1479-2008
  • Event Initiated Date
    2008-02-13
  • Event Date Posted
    2008-07-23
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2008-07-28
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Pedicle screw spinal system - Product Code NKB
  • Reason
    Screw head dissociation: the polyaxial screw head may dissociate from screw shaft during surgery. also, the polyaxial screw driver is experiencing difficulty (broken/bent driver shafts, difficulty attaching screws to the driver and jamming of the collet.).
  • Action
    The recalling firm notified sales reps regarding the recall by phone on 02/13/08. The sales reps were instructed to discontinue kit use in surgeries and to return inventory. Surgeons who had used the Sequoia System in surgery were notified of the recall via letter on 02/20/08. Surgeons were asked to monitor for post-operative dissociation in implanted patients and to notify Abbott Spine sales reps if any incidences occur.

Device

  • Model / Serial
    Part Numbers: 3300-0001-PL and 3300-0002-PL.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Nationwide Distribution including states of AR, AZ, CA, CT, CO, FL, IL, MD, MI, MN, NC, OH, OK, OR, PA, TX, VA and WI.
  • Product Description
    Sequoia Spinal System Surgical Kits; Pedicle screw spinal system; Non-sterile (kits intended to be sterilized prior to use); Rx Only; || The Sequoia Spinal System is designed to aid in the surgical correction of several types of spinal conditions. The product is a system of smaller devices used to provide stabilization during the development of a solid fusion mass.