Recall of Device Recall Sabraset Administration Sets with Auto Clamp

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Baxter Healthcare Corp..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    30506
  • Event Risk Class
    Class 2
  • Event Number
    Z-0386-05
  • Event Initiated Date
    2004-11-19
  • Event Date Posted
    2005-01-08
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2006-06-28
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Set, Administration, Intravascular - Product Code FPA
  • Reason
    A missing platen assembly in the cassette of the solution sets results in the infusion pump being unable to occlude the tubing of the set. this can lead to free-flow of the solution and a possible overdose of medication to the patient.
  • Action
    Urgent Product Recall letters dated 11/19/04 were sent to the direct accounts on the same date via UPS ground. The accounts were informed that free-flow situations were associated with the listed product codes and lot numbers due to a missing platen assembly in the cassette of the solution sets, which could result in an overdose of medication to the patient. The accounts were requested to stop use of the affected lot numbers and product codes and return the sets to Baxter c/o NNC Group, 2670 Executive Dr., Indianapolis, IN 46241, following the enclosed instructions. Any questions concerning the return process were directed to NCC at 1-866-300-5085. Any medical or technical questions were directed to Baxter at 1-800-422-9837.

Device

  • Model / Serial
    Product codes 560500-100 and 560500-250, all lot numbers other than lots produced within the range of 417519 to 499999, or those with an adhesive circular colored sticker (Avery dot) at the top of the individual package on the Tyvek side or on the shipper label.  Any lot numbers from the following obsolete Sabraset product codes are also being recalled: 5600PM, 560100, 560101, 560110, 560111, 560112, 560112-GEL, 560112-L, 560113, 560115, 560116, 560122-L, 561101, 567100, 567100-L, 567112-L, 567122-L, 569100, 569111, 569122, 560200-100, 560522-100
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide, including Puerto Rico, and internationally to Australia, Belgium, Canada, Hong Kong, Israel, Japan, Singapore, Sweden and Switzerland
  • Product Description
    Sabraset Administration Sets with AutoClamp; for use with model 6060 multi-therapy pumps only; a prescription, sterile, non-pyrogenic fluid pathway; Manufactured for Baxter Healthcare Corporation, Deerfield, IL 60015 U.S.A., the following sets were made in Mexico: || a) Sabraset 56050 ¿ 100 Administration Set with 100 mL Bag and Cassette, 56'', Volume 3 mL, 100 mL Bag with Fill Port, Cassette with AutoClamp Device, Slide Clamp, Male Luer Lock Adapter || b) Sabraset 56050 ¿ 250 Administration Set with 2500 mL Bag and Cassette, 53'', Volume 3 mL, 250 mL Bag with Fill Port, Cassette with AutoClamp Device, Slide Clamp, Male Luer Lock Adapter
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Baxter Healthcare Corp., Rt. 120 & Wilson Rd, Round Lake IL 60073
  • Source
    USFDA