Recall of Device Recall RX ACCULINK Carotid Stent System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Abbott Vascular-Cardiac Therapies dba Guidant Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    53607
  • Event Risk Class
    Class 2
  • Event Number
    Z-0749-2010
  • Event Initiated Date
    2009-10-01
  • Event Date Posted
    2010-01-29
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2011-09-27
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Carotid Stent System - Product Code NIM
  • Reason
    The recall was initiated after abbott vascular discovered, through internal testing, that the affected lot may not meet our quality specifications for catheter shaft tensile strength.
  • Action
    Abbott Vascular's Sales Representatives initiated customer contact with the identified consignees beginning October 1, 2009 . They provided the consignees with a recall letter with attached fax-back effectiveness check form. The recall letter instructed the consignees to work with their local account representative to review their inventory, complete the attached recall effectiveness check form and return identified products to Abbott Vascular. For further information, contact Abbott Vascular Customer Service at 1-800-227-9902.

Device

  • Model / Serial
    Lot Number: 9081851
  • Product Classification
  • Device Class
    3
  • Implanted device?
    Yes
  • Distribution
    Nationwide Distribution.
  • Product Description
    RX ACCULINK Carotid Stent System, 10x40 mm, Product Number: 1011344-40, Lot Number: 9081851. || Indicated for the treatment of patients at high risk for adverse events from carotid endarterectomy who require carotid revascularization.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Abbott Vascular-Cardiac Therapies dba Guidant Corporation, 26531 Ynez Rd, Temecula CA 92591-4630
  • Source
    USFDA