Recall of Device Recall Reliance Endoscope Processing System (REPS)

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Steris Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    66247
  • Event Risk Class
    Class 2
  • Event Number
    Z-2263-2013
  • Event Initiated Date
    2013-08-29
  • Event Date Posted
    2013-09-20
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2014-07-03
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Accessories, germicide, cleaning, for endoscopes - Product Code NZA
  • Reason
    The air pipe that delivers unfiltered ambient air from the procedure room into the water bottle on the listed fujinon g5 & g8 type flexible gi endoscopes does not connect to the main air/water channel within the light guide (lg) connection head and, as a result, the air pipe does not receive forced flow during the reliance eps processing cycle.
  • Action
    Steris sent an "URGENT PRODUCT SAFETY NOTICE" dated September 5, 2013 to all affected customers. The letter identified the product, problem, and actions to be taken by the customers.

Device

  • Model / Serial
    Model #'s: MB30001, MB30002, MB30003, MB000077, MB000078, MB000079, MB000080 and MB000081. Serial number range 3625606001 - 3608912002
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution-USA (nationwide) including the states of AK, CO, FL, GA, HI, ID, IL, KS, LA, MD, MN, MO, MT, NE, NM, OH, PA, SC, UT, & WY and the countries of Australia, Canada & Spain.
  • Product Description
    Reliance Endoscope Processing System (REPS), STERIS Corporation, 5960 Heisley Road, Mentor, OH 44060-1834 USA www.steris.com. || The intended use of the REPS is washing and high level disinfection of up to two manually pre-cleaned, immersible, reusable, heat-resistant, semi-critical devices.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Steris Corporation, 5960 Heisley Rd, Mentor OH 44060-1834
  • Manufacturer Parent Company (2017)
  • Source
    USFDA