Recall of Device Recall Panoramic Xray Model PC1000

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Panoramic Rental Corp..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    71653
  • Event Risk Class
    Class 2
  • Event Number
    Z-2538-2015
  • Event Initiated Date
    2015-06-04
  • Event Date Posted
    2015-09-01
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-05-30
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Unit, x-ray, extraoral with timer - Product Code EHD
  • Reason
    Jackscrew nut part failure potentially leading to device malfunction and patient/operator injury.
  • Action
    The firm, Panoramic Corporation, sent an "URGENT: MEDICAL DEVICE RECALL" letter dated 7/17/2015 via certified mail to customers on 7/20/2015, with response forms for customers to complete and return. The firm previously issued "IMPORTANT SERVICE BULLETIN" notices in 2003 and 2008 via FED-EX. The letter describes the product, problem and actions to be taken. The customers are instructed to select to use several options including replacing the failing part with one containing the safety feature, or trading in their machine for a newer one; discontinue using the devices immediately regardless the option you select, and complete and return the attached response card via email to recall@pancorp.com or fax to 260-489-5683. If the machine has been sold or donated to another dental outfit, the customer should notify Panoramic so that they can update their records. When the customer is reached, the firm will confirm whether or not the machine is still in service. Customers with questions may contact 800-654-2027 Monday through Thursday 8:00 AM to 6:00 PM and Friday 8:00 AM to 5:00 PM EST to discuss these options and determine which is best for their practice.

Device

  • Model / Serial
    Model Number: 800724-1, 800724-3; Serial Numbers 6001 to 13885, Manufactured Between 1996 and 2003
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide distribution: US (nationwide) all 50 states, including Puerto Rico; and countries of Antigua, Armenia, Aruba, Austria, Canada, China, Colombia, Ecuador, Egypt, England, France, Germany, Greece, Haiti, Honduras, Indonesia, Japan, Kenya, Lithuania, Mexico, Panama, Saudi Arabia, Singapore, Taiwan, Turkey, UAE, Uganda, Venezuela, Vietnam, and Virgin Islands.
  • Product Description
    Panoramic X-ray Model PC-1000 || The PC-1000 will enable the user to take panoramic x-ray images. The PC-1000/Laser 1000 will enable the user to take panoramic x-ray images as well as cephalometric x-ray images.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Panoramic Rental Corp., 4321 Goshen Rd, Fort Wayne IN 46818-1201
  • Manufacturer Parent Company (2017)
  • Source
    USFDA