Recall of Device Recall Nemio XG SSA580A, Diagnostic Ultrasound System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Toshiba American Med Sys Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    37813
  • Event Risk Class
    Class 2
  • Event Number
    Z-0771-2007
  • Event Initiated Date
    2006-12-19
  • Event Date Posted
    2007-05-05
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2012-02-15
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Diagnostic Ultrasound System - Product Code ITX
  • Reason
    Transducer surface temperature : it was found during testing that when using the system in the 2dcdi + pw mode, with the scale graph function active, that the transducer surface temperature could exceed the 27 degrees celsius limit as specified in the iec safety standard.
  • Action
    Notification letters were sent to customers on December 19, 2206. Customers were instructed to avoid using Scale Graph function with live images, and instructed to call up the Scale Graph after images are frozen. Customers were informed that a Toshiba Customer Service Engineer will contact them to schedule a software upgrade when software becomes available. If customers have any questions they were instructed to contact their Toshiba Customer Service Engineer or call (800) 421-1968 and ask for the Regulatory Affairs Department. Customers were also instructed to distribute this information to all users of the product and also with the Bio-medical Department at their facility.

Device

  • Model / Serial
    Serial #: A1A0642100; A1A0642102; A1B0662183; A1B0662184; A1B0662256; A1B0662257; A1B0662258; A1B0662327; A1B0662328; A1B0662330; A1B0662331; A3A0652115; A3B0662284; A3B0662285; A3B0662286; A3B0662287; A3B0662288; A3B0662289; A3B0662290; A3B0662291; A3B0662292; A3B0662293; A3B0662371; A3B0662372; A3B0662373; A3B0662374; A3B0662375; A3B0662376; A3B0662377; A3B0662378; A3B0662379; A3B0662380; A3B0672415; A3B0672416; A3B0672417; A3B0672418; A3B0672419;
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Nationwide Distribution including the states of CA, FL, GA, ID, MA, MN, NC, NY, PA, RI, TN, TX, WA, and WI.
  • Product Description
    Nemio XG, ultrasound system, SSA-590A with version 1.5 software, Toshiba American Medical Systems, Inc., Tusin, CA.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Toshiba American Med Sys Inc, 2441 Michelle Dr, P.O. Box 2068, Tustin CA 92781-2068
  • Source
    USFDA