Recall of Device Recall MINDFRAME CAPTURE(TM) LP Revascularization Device

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Micro Therapeutics Inc, Dba Ev3 Neurovascular.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    79463
  • Event Risk Class
    Class 1
  • Event Number
    Z-1701-2018
  • Event Initiated Date
    2018-02-26
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Catheter, thrombus retriever - Product Code NRY
  • Reason
    There is a potential issue for all mindframe capture devices to partially detach or separate from the delivery wire.
  • Action
    The firm initiated their recall via an Urgent Medical Device Recall letter, dated February 26, 2018. The letter identified the affected device, described the issue, product scope, and the actions to be taken. The firm recommended users remove and quarantine all affected and unexpired product in their inventory and return the affected products to Medtronic. Customers may contact their Medtronic representative if alternative product is needed. The Customer Confirmation Form should be completed and faxed to Medtronic at 1-949-434-5020, to the attention of Neurovascular Quality.

Device

  • Model / Serial
    All lot numbers: Product Number: UDI (a) REF 300010: 00843889031334, 00843889031341, 00847536020207 (b) REF 300011: 00843889031365, 00843889031372, 00847536020214 (c) REF 300012: 00843889031396, 00843889031402, 00847536020221 (d) REF 300013: 00843889031426, 00843889031433, 00847536020238 (e) REF 300014: NOT DISTRIBUTED (f) REF 300015: 00847536020122, 00847536020160 (g) REF 300016: 00847536020139, 00847536020177 (h) REF 300017: 00847536020146, 00847536020184 (i) REF 300018: 00847536020153, 00847536020191
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution
  • Product Description
    MindFrame Capture LP Revascularization Devices: Product Numbers: || (a) REF 300010 || (b) REF 300011 || (c) REF 300012 || (d) REF 300013 || (e) REF 300014 || (f) REF 300015 || (g) REF 300016 || (h) REF 300017 || (i) REF 300018 || Intended to restore blood flow by removing thrombus from a large intracranial vessel experiencing ischemic stroke within 8 hours of symptom onset.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Micro Therapeutics Inc, Dba Ev3 Neurovascular, 9775 Toledo Way, Irvine CA 92618-1811
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    USFDA