Recall of Device Recall Medtronic KYPHON(R) Express(TM) Directional Bone Filler Device

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Medtronic Sofamor Danek USA Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    78790
  • Event Risk Class
    Class 2
  • Event Number
    Z-0352-2018
  • Event Initiated Date
    2017-12-06
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Injector, vertebroplasty (does not contain cement) - Product Code OAR
  • Reason
    Medtronic has discovered the directional arrow at the proximal end of the instrument may not correctly align with the cut out opening on the distal end of the instrument.
  • Action
    Medtronic distributed a voluntary removal notice via FedEx courier service to impacted U.S. consignees on 06 DEC 2017. The recall notice stated the following: "If he/she has not already done so, your Sales Representative will contact you to facilitate the return of any impacted products you may have in your possession. Please disseminate this information to additional personnel within your facility as appropriate, and maintain a copy of this notice in your records. Instructions to Customers: 1.) Please locate and remove the impacted product from normal storage locations. Do not use this product. 2.) Complete the enclosed Customer Confirmation Form and return 3.) As applicable, contact your Medtronic Sales Representative to coordinate the return and replacement of affected product."

Device

  • Model / Serial
    UDI 00643169097254 Lot Numbers: WI424428, WI428822, WI435227, WI439940, WI442555, WI446722, WI449819, WI455595, WI459477, WI463434, WI472175, WI472178, WI472176, WI472177, WI474575
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    US. Austria, Belgium, Bulgaria, Canada, France, Germany, Italy, Lebanon, Luxembourg, Portugal, South Africa, US
  • Product Description
    Medtronic KYPHON(R) Express(TM) Directional Bone Filler Device, SIZE 2, REF FB, QTY 1 EA, Rx only STERILE R
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Medtronic Sofamor Danek USA Inc, 1800 Pyramid Pl, Memphis TN 38132-1703
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “If our surveillance systems identify a potential performance issue, our personnel promptly evaluate the problem, including, when appropriate, conducting root cause investigations and internal testing to assess whether the product continues to meet specifications and defined performance criteria,” Medtronic told ICIJ in a statement. “In some cases, based on this evaluation, Medtronic may determine that a recall is necessary.” The company said that it communicates with healthcare providers and/or patients and provide recommendations to address such issues. Medtronic noted that these communications can include letters, emails, calls, press releases, physician notifications and social media postings, as well as informing the FDA and other regulators of the actions.
  • Source
    USFDA