Recall of Device Recall Maquet Cardiopulmonary Heater Cooler Unit HCU30 Type 2

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Maquet Cardiovascular Us Sales, Llc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    72652
  • Event Risk Class
    Class 2
  • Event Number
    Z-0589-2016
  • Event Initiated Date
    2015-11-13
  • Event Date Posted
    2016-01-05
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-04-07
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Controller, temperature, cardiopulmonary bypass - Product Code DWC
  • Reason
    Failure of the heater-cooler unit (hcu 30) type 2 power supply board. a drop of more than 10% voltage can cause overheating and subsequent failing of the r56 thermistor of the power supply board. board failure typically occurs when the compressor is switched on (prior to patient use); however, it can occur during patient use. this can shut down the compressor or the entire hcu 30 type 2 unit.
  • Action
    MAQUET sent "Product Recall Urgent Medical Device Field Correction" notices and "Medical Device Field Correction Response Forms" dated 11/13/2015 via UPS to affected customers. The notification identified the issue and how to identify the affected unit. The notification instructed customers to always keep a replacement heater-cooler unit on standby in the event of a unit failure; complete the attached Field Correction Response form (fax to 1.973.629.1518 or email to HCU30@maquet.com; and that they would be contacted by a representative of the Maquet Service Team to schedule an onsite service to determine if the power supply board in their HCU 30 Type 2 unit is affected adn replace the power supply board as necessary. If the customer had any questions they are instructed to contact their Maquet Service Representative or Maquet Technical Support at 1.888.627.8383 (Press option 3, followed by Option 1 and then option 1 again), Monday through Friday between the hours of 8:00 am and 5:00 pm.

Device

  • Model / Serial
    HCU 30 Base Unit 100 - 120 V, Model Number 704629/70103.4371 HCU 30 Base Unit 200 - 240 V, Model Number 704631/70103.4642 HCU 30 Base Unit Canadian/US, Model Number 705501/70103.4653 Heater Cooler Unit 30 with Serial Number <93101480  The affected power supply boards have serial numbers less than 107006001.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    United States Nationwide Distribution
  • Product Description
    Maquet HCU 30 Coolant Type R134A Filling weight 250 g 120 V 50-60 Hz 1920 W || Product Usage: The Heater Cooler Unit (HCU) 30 is intended to circulate water through heat exchange circuits to warm or cool a patient during short duration cardiopulmonary bypass procedures lasting 6 hours or less.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Maquet Cardiovascular Us Sales, Llc, 45 Barbour Pond Drive, Wayne NJ 07470
  • Manufacturer Parent Company (2017)
  • Source
    USFDA