Recall of Device Recall MagNA Pure 24 System Pathogen Protocols

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Roche Molecular Systems, Inc..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    79899
  • Event Risk Class
    Class 2
  • Event Number
    Z-1956-2018
  • Event Initiated Date
    2018-05-02
  • Event Status
    Open, Classified
  • Event Country
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Clinical sample concentrator - Product Code JJH
  • Reason
    Cross-contamination of samples has been reported when running the existing protocol on the system with the rack-based purification run.
  • Action
    Customers were notified of the field action by letter on 4/27/18. The letter included the following required actions: " If you used the MagNA Pure 24 Pathogen 200 and/or Pathogen 1000 protocols to extract nucleic acids for an assay for a chronic infectious disease (e.g., Hepatitis C Virus), then suspected false positives should be evaluated further following local procedures and retested as necessary. " Complete the attached fax form and fax it to 1-844-861-6232 or email it to roche6612@stericycle.com. " File this Urgent Medical Device Correction (UMDC) for future reference.

Device

  • Model / Serial
    Device Identifier: 07613336106174
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution - US Nationwide in the states of: CA, GA, HI, IN, MD, ME, MI, MN, NC, NY, PA, VI, and WI. The products were distributed to the following foreign countries: Austria, Belgium, Brazil, Chile, China, Columbia, Costa Rica, Czech Republic, Denmark, France, Germany, Guatemala, Hong Kong, Hungary, India, Israel, Italy, Japan, Mexico, Netherlands, Norway, Poland, Singapore, Slovenia, South Africa, South Korea, Spain, Switzerland, Taiwan, UAE, United Kingdom, Vietnam.
  • Product Description
    MagNA Pure 24 System, GMMI: 07290519001 || Product Usage: || The MagNA Pure 24 System is a fully automated clinical sample extractor. It extracts nucleic acids from various sample types, sample tubes, and volume inputs for multiple downstream applications. The main features of the system are : Scalable purification of 1 to 24 samples Primary/secondary tube handling Inventory and sample management via barcodes Efficient order management via host The MagNA Pure 24 System offers 4 run types: Purification (rack) run Purification (cartridge) run Post Elution run Sample transfer run
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Roche Molecular Systems, Inc., 1080 US Highway 202 S, Branchburg NJ 08876-3733