Recall of Device Recall Integra Advansys Medial Lisfranc Plate (MLP)

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Integra LifeSciences Corp..

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    61655
  • Event Risk Class
    Class 2
  • Event Number
    Z-2123-2012
  • Event Initiated Date
    2012-02-09
  • Event Date Posted
    2012-08-01
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2013-02-19
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Plate, fixation, bone - Product Code HRS
  • Reason
    Incorrect technique applied may cause potential rupture of the tibialis anterior tendon during surgery.
  • Action
    INTEGRA sent an Urgent Medical Device Correction Notice dated February 10, 2012, to all affected customers. The letter identified the product, the problem, and the action to be taken by the customer. Customers were asked to identify members of surgical team that ues the affected product and make them aware of the Medical Device Correction Notice. Customers were asked to sign and return the enclosed Medical Device Correction Notice Acknowledgement and Return Form and to maintain a copy of the notification and signed copy of the acknowledgment form for their records. For any questions regarding this recall call 609-936-6832..

Device

  • Model / Serial
    Model #181041S, Batch #s EKU8, EN2D, EN2B, EMOK & EN2B; Model #181051S, Batch #s EJQY, FOSU, ECEB & E179; Model #181041, Batch #s EB1E, EBKY, ECE9, EHA7, E647, E8NP, E8P7, E8ML, E8N5, E8PV, E8N5 & E5GV; Model #181042, Batch #s E648, EB1F, E8MM, E8NQ, E8PW, E5GW, E8N6, E8P8, E5GY, E8PW & EBKZ; Model #181052, Batch #s E5GY, E64A, E8PY, E5GW, E8PA, E8NS, E8N8, E8MP & EB1H; Model #181051, Batch #s E649, E5GX, E8MN, E8N7, E8P9, E8NR, E8PX, ECEB, EJ79, EB1G, EBLO & ECEB; Model #181052S, Batch #s E8PY, EB1H, EB14 & E8MP; Model #181042S, Batch #s E8MM, EB1F & EBKZ.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide Distribution - USA including AK, AL, AR, AZ, CA, CO, CT, DC, FL, GA, IA, ID, IN, KS, KY, LA, MA, MD, MI, MN, MO, NC, NE, NH, NM, NJ, NY, NV, OH, OK, OR, PA, RI, SC, TN, TX, UT, VA, WA & WI and internationally to Belgium; Danemark; France; Germany; Isra¿l; Italy; Lebanon; Luxemburg; Netherlands; Norway; Portugal; Saudi Arabia; Spain; Switzerland; Turkey & United Kingdom.
  • Product Description
    Integra¿ Advansys Medial Lisfranc Plate (MLP), Integra, 311 Enterprise Drive, Plainsboro, NJ 08536 || The Advansys plates are intended for bone fixation such as: Arthrodesis of the 1st metatarsocuneiform joint to reposition and stabilize a metatarsus primus varus, Lisfranc arthrodesis, Mono or bi-cortical osteotomies or fractures near the 1st metatarsocuneiform joint.