Recall of Device Recall HydroThermAblator Endometrial Ablation System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Boston Scientific Corporation.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    52780
  • Event Risk Class
    Class 2
  • Event Number
    Z-2209-2009
  • Event Initiated Date
    2009-07-31
  • Event Date Posted
    2009-09-22
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2011-05-03
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Endometrial Thermal Ablation Device - Product Code MNB
  • Reason
    Cracked procedure sheaths, incorrect care/use of device, and console malfunctions may result in fluid leaks and loss of a cervical seal that are responsible for burns.
  • Action
    Boston Scientific issued an Urgent Medical Device Recall - Immediate Action Required notification to hospitals and distributors dated July 31, 2009 via Federal Express and requested the immediate discontinued use and segregation of Recall product for return and Complete and return the Reply Verification Tracking Form. An email was sent to Physicians to provide the recall information. Boston Scientific issued a Clarification letter dated August 6, 2009 via Federal Express as a follow-up to the July 31, 2009 Recall letter for the following reason: customers may remove product from the outer box and store it on the inventory shelf by the inner package only. If this is a practice at the facility, a customer must consider both the inner and outer packaging product codes when searching for affected recalled product as the UPN numbers on the inner and outer labeling are different. A reply verification tracking form for customers was provided in case they have located any additional product to return.

Device

  • Model / Serial
    Lot Numbers: 35421, 35422, 35423, 35424, 35425, 35426, 35846, 35847, 35890, 35891, 35892, 36038, 36039, 36040, 36041, 36042, 36047, 36048, 36104, 36105, 36141, 36142, 36143, 36146, 36147, 36148, 36214, 36215, 36234,36235, 36249, 36250, 36251, 36260, 36261 ,36370, 36371, 36372, 36467, 36468, 36682, 36683, 36684, 36685, 36686, 36688, 36689, 36690, 36693, 36694, 36695, 37049, 37098, 37099, 37149, 37150, 37151, 37154, 37192, 37218, 37219, 37220, 37221, 37222, 3and 7223.
  • Product Classification
  • Device Class
    3
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution -- USA, Austria, Denmark, Finland, France, Great Britain, Italy, Netherlands, and Sweden.
  • Product Description
    Boston Scientific HydroThermAblator Endometrial Ablation System- || HTA¿ System Procedure Set with Tenaculum Stabilizer and Disposable Heater Canister (5/bx) || Material/UPN/Catalog Number: M006560201 || System-HTA¿ System Procedure Set with Tenaculum Stabilizer and Disposable Heater Canister (ea) || Material/UPN/Catalog Number: M006560200 || Intended to ablate the endometrial lining of the uterus in premenopausal women with menorrhagia due to benign causes for whom childbearing is complete.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Boston Scientific Corporation, 100 Boston Scientific Way, Marlborough MA 01752-1234
  • Manufacturer Parent Company (2017)
  • Manufacturer comment
    “We take a patient-first approach to assessing the applicability of every recall and communicate to regulatory bodies in all geographies where the recalled device is sold,” Boston Scientific said in a statement to ICIJ. “We have coordinated several recalls across many countries in a timely manner,” the company said, adding that it complies with all national laws, which can often vary and require different processes for reporting information or taking action on recalls. The company said it uses a rigorous and uniform process to take action on recalls and that “when we initiate a field action (e.g. recall, safety alert), every customer who has received an affected product receives a communication that includes a letter for the physician.”
  • Source
    USFDA