Recall of Device Recall GE Centricity Laboratory Instrument Interface Data Innovations Instrument Manager Software

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Ge Healthcare It.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    58676
  • Event Risk Class
    Class 2
  • Event Number
    Z-2563-2011
  • Event Initiated Date
    2011-05-03
  • Event Date Posted
    2011-06-14
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2011-10-04
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Calculator/data processing module, for clinical use - Product Code JQP
  • Reason
    The ge centricity laboratory instrument interface to data innovations is processing a preliminary result instead of the final result from the process system manager when there is a test rerun conducted.
  • Action
    GE Healthcare sent an "URGENT MEDICAL DEVICE CORRECTION" letter dated May 3, 2011 to all affected customers. The letter describes the product, problem, and action to be taken by the customer. The letter provided the users with specific safety instructions to follow until the software was updated. The customers were requested to complete the enclosed customer reply form and fax the completed form to 847-620-2780. Any questions should be directed to their GE Service Representative or the GE Help desk at 888-778-3375.

Device

  • Model / Serial
    Versions 3.3, 4.0 and 4.1
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution-- USA (nationwide) including states of Georgia, New York, Ohio, Oregon, and Tennessee and countries of Canada, England, and Qatar.
  • Product Description
    GE Centricity Laboratory Instrument Interface to Data Innovations Instrument Manager software; GE Healthcare IT Solutions, Barrington, IL 60010. || The Centricity Laboratory is designed to facilitate the general clinical, anatomic pathology and cytology laboratory workflow such as order entry, results entry, instrument interfacing, results reporting and patient record retrieval. It integrates with other Hospital Information Systems (HIS) through HL7 interface by order entering and report processing. The centricity is intended to interface with various lab devices through standard HL7 interfaces to record, report and distribute lab results.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Ge Healthcare It, 540 W Northwest Hwy, Barrington IL 60010-3051
  • Manufacturer Parent Company (2017)
  • Source
    USFDA