Recall of Device Recall FOCAL Workstation

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Computerized Medical Systems Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    58250
  • Event Risk Class
    Class 2
  • Event Number
    Z-2599-2011
  • Event Initiated Date
    2009-02-06
  • Event Date Posted
    2011-06-20
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2014-04-08
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    System,planning,radiation therapy treatment - Product Code MUJ
  • Reason
    Focal software: if individual mlc leaf position edits are made, the original mlc aperture is retained. a subsequent aperture edit should not affect the mlc leaf positions however it was found that instead the leaves will then snap (unintentionally) back to the original aperture. also, if the patient is sent to xio after the mlc is edited, an isocenter shift made in xio will also cause the mlcs to.
  • Action
    Elekta CMS Software sent an "ADVISORY NOTICE" dated February 6, 2009 to its affected customers. The notice identified the product, the problem, and the actions to be taken. Customers were informed that the workaround method available is to (edit the MLC pattern using the aperture first and the individual MLC leaf edits second). The firm states that this issue will be resolved in Focal version 4.50.00 and above. A "User Notice" will be sent to all users still using the affected software notifying them of the updated software available to correct the problem. If you have any questions, please call 314-993-0003 or toll free 800-878-4267.

Device

  • Model / Serial
    Focal Release 4.1.1 through 4.40.00
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    Worldwide Distribution -- USA (nationwide) including the state of: Puerto Rico and countries of: Albania, Algeria, Argentina, Australia, Austria, Azerbaijan, Belarus, Belgium, Bosnia and Herzegovina, Brazil, Canada, Chile, China, Colombia, Costa Rica, Croatia, Czech Republic, Egypt, Estonia, France, Germany, Hungary, India, Israel, Italy, Japan, Malaysia, Mexico, Mongolia, Morocco, Netherlands, New Zealand, Nicaragua, Peru, Philippines, Poland, Portugal, Qatar, Romania, Russia, Saudi Arabia, Serbia, Singapore, Slovenia, South Africa, South Korea, Spain, Sudan, Switzerland, Taiwan, Thailand, Turkey, Turkmenistan, United Kingdom, Uruguay and Venezuela.
  • Product Description
    Focal Radiation Treatment Planning System, Focal Release 4.1.1 through 4.40.00. || Product Usage: for use in radiation treatment planning using generally accepted contouring methods. The Focal software allows users to access XiO and other RTP systems from a remote PC-based system and provides the user with the ability to edit and modify patient data from a Windows-based PC and transfer the information back to the RTP system.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Computerized Medical Systems Inc, 13723 Riverport Drive, Suite 100, Maryland Heights MO 63043
  • Manufacturer Parent Company (2017)
  • Source
    USFDA