Recall of Device Recall Engstrom Carestation

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Datex - Ohmeda, Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    37105
  • Event Risk Class
    Class 2
  • Event Number
    Z-0784-2007
  • Event Initiated Date
    2007-02-02
  • Event Date Posted
    2007-05-10
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2008-10-16
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Critical Care Ventilator - Product Code CBK
  • Reason
    There are two unique conditions with the engstrom carestation that require corrective action. these include an anomaly in the control of the safety relief valve and a situation where the display unit may reset.
  • Action
    Device Correction Letter to customers was mailed on 2/2/07 giving information about the correction and a short term recommendation until version 4.15 could be installed by a GE representative who would be contacting the customer.

Device

  • Model / Serial
    Serial numbers: CBCH00101, CBCH00110, CBCJ00135, CBCJ00136, CBCJ00207, CBCJ00472, CBCJ00623, CBCJ00685, CBCJ00686, CBCJ00688 thruCBCJ00702, CBCK00100, CBCK00101 thru CBCK00208, CBCK00210 thru CBCK00269, CBCK00271 thru CBCK00298, CBCK00301 thru CBCK00516, CBCK00519 thru CBCK00526, CBCK00535
  • Product Classification
  • Device Class
    2
  • Implanted device?
    No
  • Distribution
    GA, RI, WI, TX. Foreign - AUSTRALIA, BRUNEI DARUSSALAM, BRAZIL, COLOMBIA, COSTA RICA, SPAIN, FINLAND, FRANCE, UNITED KINGDOM, INDIA, ITALY, KOREA, MEXICO, MALAYSIA, PHILIPPINES, SAUDI ARABIA, SWEDEN, SINGAPORE, GERMANY.
  • Product Description
    GE Healthcare Engstrom Carestation Critical Care Ventilator with the High Performance Display Unit with SW version 3.x and 4.11; identification numbers 1505-9000-000 and M1057699 (upgrade). Datex-Ohmeda, Inc., a General Electric Company, doing business as GE Healthcare, P.O. Box 7750, Madison, WI 53707-7550, USA, www.gehealthcare.com.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Datex - Ohmeda, Inc, 3030 Ohmeda Drive, PO Box 7550, zip 53707-7550, Madison WI 53707-7550
  • Source
    USFDA