Recall of Device Recall Enduramesh Corpectomy Spacer System

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Lucero Medical LLC.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    62926
  • Event Risk Class
    Class 2
  • Event Number
    Z-2368-2012
  • Event Initiated Date
    2012-07-15
  • Event Date Posted
    2012-09-11
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2013-02-20
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Spinal vertebral body replacement device - Product Code MQP
  • Reason
    The firm voluntarily recalled the device after they discovered that the sterilization recommendations on the product insert did not pass sterilization validation.
  • Action
    Lucero Medical sent a Field Correction Notice letter dated July 15, 2012 to it's sole consignee. The notice identified the affected product., problem and actions to be taken. The customer was instructed to complete the response card and submit back to their local Lucero Medical Representative.

Device

  • Model / Serial
    Part #-Lot # (s): 762.010L-110738; 762.013L-110738; 762.017L-60611, 90611, and 512171; 762.019L-60611, 90611, 100308, 1261901, and 20121901; 762.021L-60611, 90611, 100308, 110106, 20122101, and 20122102; 762.023L- 90611, 100209, 100218, 00706, 10709, 20122301, and 20122302; 762.025L-90611, 100218, 110106, 20122501, and 20122502; 762.027L-60611, 90611, 100706, and 20122071; 762.029L-90611, 1262901, and 90611; 762.031L-1263101; 762.033L-90611, 91002, and 1263301; 762.041L-90611 and 1264101; 762.043L-90611 and 1264301; 762.045L-90611; 762.047L-90611; 762.049L-90611; 762.051L-90611 and 512511; 762.053L-90611; 762.090L-90611; 762.090L-2.0-100206 and 100342; 762.090L-2.5-100206; 762.159L-110505; 762.237L-91002; 762.243L-91018; 762.270L-91018; 762.290L-91018; 762.731L-91018; 762.735L-91002; 762.767L-91018; and 762.790L-91018.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    US Nationwide Distribution
  • Product Description
    Enduramesh Corpectomy Spacer System || Product Usage: The Enduramesh is a vertebral body replacement system intended for use in the thoracic and lumbar spine (T1-S1) to replace a collapsed, damaged or unstable vertebral body due to tumor or trauma/fracture. The device is intended for use with either allograft or autograft. The device may be used with a cleared supplemental fixation system based on surgeon discretion and preference.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Lucero Medical LLC, 6100 Oak Tree Blvd Ste 200, Independence OH 44131-6914
  • Manufacturer Parent Company (2017)
  • Source
    USFDA