Recall of Device Recall Endopath

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Ethicon Endo-Surgery Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    74701
  • Event Risk Class
    Class 2
  • Event Number
    Z-0296-2017
  • Event Initiated Date
    2016-07-15
  • Event Date Posted
    2016-10-20
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2017-02-28
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Staple, implantable - Product Code GDW
  • Reason
    Quality control identified a component issue where the pinion gear in the device could fail under extreme use cases. if this condition occurs, staples will be formed past the cut line and the device can be opened and removed from the patient. the firing stroke may be interrupted and the knife may not fully return to the home position potentially exposing the healthcare professional to a sharps injury.
  • Action
    Ethicon sent an Urgent Medical Device Recall letter dated July 15, 2016, to all affected consignees via UPS next day mail. The letter identified the product, the problem, and the action to be taken by the customer. Consignees were instructed to examine their inventory immediately and quarantine any affected product and return to ENDOPATH. If product subject to the recall was further distributed consignees were instructed to notify the other facility and arrange for return of the affected product. Customer were instructed to complete the Business Reply Form confirming receipt of this letter and fax to Stericycle at 1-888-228-5719 or email to ethicon5182@stericycle.com. Customers with questions were instructed to contact the Ethicon Customer Support Center at 1-877-384-4266. For questions regarding this recall call 513-337-3582.

Device

  • Model / Serial
    N91L2N, N91L2P, N91N1J, N91N1K, N91L0T, N91L0U, N91N29,  N91N2G, N91R8X, N91R8Y.
  • Product Classification
  • Device Class
    2
  • Implanted device?
    Yes
  • Distribution
    Worldwide Distribution - US including AL, AR, AZ, CA, CO,CT, DC, FL,GA, IA,IL,KS,KY,LA,MA,MD, ME, MI,MN,MO, MS, MT,NC, ND, NH,NJ, NM, NV, NY, OH, RI, TN, TX, VA, VT, WA, WI and Internationally to Brazil and Canada.
  • Product Description
    Endoscopic Articulating Linear Cutter, 38ATW35. VASCULAR/THIN 35MM || The ENDOPATH ETS-Flex Endoscopic Articulating Linear Cutter has application in general, gynecologic, urologic, and thoracic surgery for transection, resection, and/or creation of anastomoses
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Ethicon Endo-Surgery Inc, 4545 Creek Rd, Blue Ash OH 45242-2803
  • Manufacturer Parent Company (2017)
  • Source
    USFDA