Recall of Device Recall Drugs of abuse urinalysis (DAU) cTHC (Cannabinoid) Control Level 2 (62.5 ng/ml)

According to U.S. Food and Drug Administration, this recall involved a device in United States that was produced by Lin-Zhi International Inc.

What is this?

A correction or removal action taken by a manufacturer to address a problem with a medical device. Recalls occur when a medical device is defective, when it could be a risk to health, or when it is both defective and a risk to health.

Learn more about the data here
  • Type of Event
    Recall
  • Event ID
    67521
  • Event Risk Class
    Class 2
  • Event Number
    Z-1179-2014
  • Event Initiated Date
    2014-02-06
  • Event Date Posted
    2014-03-12
  • Event Status
    Terminated
  • Event Country
  • Event Terminated Date
    2015-03-10
  • Event Source
    USFDA
  • Event Source URL
  • Notes / Alerts
    U.S. data is current through June 2018. All of the data comes from the U.S. Food and Drug Administration, except for the category Manufacturer Parent Company.
    The Parent Company was added by ICIJ.
    The parent company information is based on 2017 public records.
  • Extra notes in the data
    Urinalysis controls (assayed and unassayed) - Product Code JJW
  • Reason
    Product catalog #s 0007c cannabinoid 37.5 ng/ml control level 1 and 0008c cannabinoid 62.5 control level 2 of the lots mentioned may give decreased concentration readings towards the end of their shelf life due to use of dated but unexpired secondary stock used to create the products.
  • Action
    Lin-Zhi International, sent an Recall letter dated February 6, 2014, to all affected customers. The letter identified the product the problem and the action needed to be taken by the customer. The Recall letter identified the product by catalog number and product description as well as lot numbers. The reason for recall is explained and that the issue was confirmed by Lin Zhi Quality Control. The 2 affected lots were made with unexpired but dated secondary stock that is the cause of the problem. Lin Zhi requests that customers inform laboratories and customers to properly dispose of any of the affected lots that are still in use or unopened. Lin Zhi should be notified of the amounts for credit. Questions should be directed to 408-732-3883.

Device

  • Model / Serial
    Catalog number 0008c; lot number 1211160R; Expiration May 14, 2014.
  • Product Classification
  • Device Class
    1
  • Implanted device?
    No
  • Distribution
    US Distribution including the states of SC, NC, LA, FL, TX,, AL and GA and Internationally to Germany.
  • Product Description
    Cannabinoids DAU Calibrator Control Level 1 || (62.5 ng/mL) || This solution is prepared from non-sterile urine and should be handled as potentially infectious. || IVD; || The Cannabinoids (cTHC also known as THC version c) DAU negative and positive controls are human urine-based liquids and ready to use. The constituent is a processed drug-free human urine matrix, containing buffers, stabilizers, and less than 0.09 % of sodium azide. The controls are prepared by spiking known concentrations of 11-nor-9-THC-9-COOH into the drug-free || matrix. cTHC is referenced as an abbreviation for 11-nor-9-THC-9-COOH and it may be referred to simply as THC in the text of this report. The controls contain 37.5 ng/mL and 62.5 ng/mL of cTHC,¿¿ 10% by GC/MS or LC/MS analysis. || Lin Zhi International inc. || Sunnyvale, CA 94085 || The Cannabinoid Drug of Abuse (DAU) negative and positive controls are used as assay quality control material to monitor the precision of the Lin-Zhi International, Inc. (LZI) Cannabinoid Enzyme Immunoassay (Ref # 0070c) on a number of automated clinical chemistry analyzers.
  • Manufacturer

Manufacturer

  • Manufacturer Address
    Lin-Zhi International Inc, 670 Almanor Ave, Sunnyvale CA 94085-3513
  • Manufacturer Parent Company (2017)
  • Source
    USFDA